Télécharger Imprimer la page

Victron energy EasySolar 12/1600/70-16 230V Manuel page 21

Publicité

5.5.2. DIP switch 3 to 7
These DIP switches can be used to set:
- Battery charge voltage and Absorption time
- Inverter frequency
- Search mode
- AC input current limit 12 A or 6 A
ds3-ds4: Setting charge voltages
Absorption
ds3-ds4
voltage
ds3=off
14.4
ds4=off
28.8
(default)
57.6
ds3=on
14.1
ds4=off
28.2
56.4
ds3=off
14.7
ds4=on
29.4
58.8
ds3=on
15.0
ds4=on
30.0
60.0
Batteries with high antimony content can typically be charged with a lower absorption voltage
than batteries with low antimony content. (Please refer to our book 'Electricity on Board'
downloadable from our website www.victronenergy.com for details and suggestions about
charging batteries). Contact your battery supplier for the correct charge voltages and change
(with VE-configure) the voltage settings if required.
The default charge current setting is 75 % of the maximum charge current. This current will be
too high for most applications.
For most battery types the optimal charge current is 0.1-0.2x the battery capacity.
ds5: Inverter frequency
ds6: Search Mode
ds7: AC input current limit
Store the settings by moving DIP switch 8 to 'on' and back to 'off'.
Absorption
Float
Storage
Time
voltage
Voltage
(hours)
13.8
13.2
27.6
26.4
8
55.2
52.8
13.8
13.2
27.6
26.4
8
55.2
52.8
13.8
13.2
27.6
26.4
5
55.2
52.8
13.8
13.2
27.6
26.4
6
55.2
52.8
off = 50 Hz
off = off
off = 12Amp
19
Suitable for
Gel Victron Deep Discharge
Gel Exide A200
AGM Victron Deep
Discharge
Gel Victron Long Life
(OPzV)
Gel Exide A600 (OPzV)
Gel MK battery
AGM Victron Deep
Discharge
Tubular plate or OPzS
batteries in semi-float mode
AGM spiral cell
Tubular plate or OPzS
batteries in cyclic mode
on = 60 Hz
on = on
on = 4Amp

Publicité

loading

Ce manuel est également adapté pour:

Easysolar 24/1600/40-16 230vEasysolar mppt 100/50