LINEA 3000
Colour video entrance panel with wide angle
camera and proximity reader
Installation and camera shooting range
The camera must not be installed in front of large light sources, or in places where the subject viewed remains in deep shadow.
In poor lighting conditions cameras with colour are less sensitive than black/white cameras.
An extra lighting source should be added in poorly lit rooms.
Configuration
The device must be (only physically) configured as follows:
P - entrance panel number
The configurator connected to the P housings of the speaker module assigns to the same
an identification number within the system.
The numbering of the entrance panels must always start from P=0.
The entrance panel configured with P=0 must be a common (or main) entrance panel.
N - call number
Assigns the correspondence between the entrance panel pushbuttons and the audio
handsets or video handsets. In the common entrance panels made with pushbutton
modules, 1 must be inserted in N of the speaker module. The number of the first riser
handset must be inserted in the local entrance panels in N.
T - door lock relay timing
configurator number
0= No
1
2
configurator
4 sec.
1 sec.
2 sec.
* Operation as pushbutton for 10 sec. max, after which standby mode is activated.
To extend operation time over 10 seconds, use actuator 346210 configured with
MOD=5.
** As pushbutton from Internal Unit or local Pushbutton.
4Sec. with release using resident Key cards.
S - type of call signal
S configuration sets the internal unit call tone and the enabling/disabling of the door
lock release notification tone generated by the entrance panel.
One can thus differentiate the calls from different entrance panels.
Table (with door lock tone enabled) for Sprint L2 internal unit call signal
Configurator
0
1
Type of bell
2-tone
2-tone
1200Hz
1200Hz
600Hz
0 Hz
Table (with door lock tone disabled) for Sprint L2 internal unit call signal
Configurator
4
5
Type of bell
2-tone
2-tone
1200Hz
1200Hz
600Hz
0 Hz
160 cm
3
4*
5
6
3 sec.
**
6 sec.
8 sec.
2
3
2-tone
One-tone
1200Hz
1200Hz
2400Hz
6
7
2-tone
One-tone
1200Hz
1200Hz
2400Hz
ST-00000758-
85 cm
(80 °)
7
10 sec.
For the Classe 100 and Classe 300 internal units, the S configurator associates the
entrance panel to the bell programmed in the internal unit.
Configurator
Configurator
In one-family systems S= 9 (door lock tone enabled) or S= 8 (door lock tone disabled)
configure the General Call and make the internal unit ring, as with S= 0 or S= 4
EN
29/07/2020
343091 - 343093
50 cm
140 cm
(105°)
0
1
2
3
4
5
6
7
Door lock tone
enabled
Door lock tone
disabled
2

Publicité

loading

Ce manuel est également adapté pour:

Linea 3000 343093