If heater does not start, turn power switch to "0" and then to "1" position. if the heater still does not start
after three times please contact your dealer.
Attention: while the heater is operating, never let the floor ground overheats to prevent causing fire.
Flameout
◆
Pay attention
1、when you shut off the heater, make sure the flame is out before you left the appliance.
2、Put the power switch to position"0" waitting fan stop working and the indicator extinguishes, then
remove the plug from the socket.
◆ safety device
Flame-out protection:Utilizes a photocell to monitor the flame in burn chamber during normal
operation.The photosensitive resistor will become infinite big , cut off Electrovalve Assy ,will stop offer
oil automatic , the fan will working 90s then cut off the power .
Electrical power breakdown protection
when the power breaks down the heater stops working without the plug being removed from the
socket . When the power is recovered, the indicator will light but the heater will not work. Please press
the power switch to start up the heater.
Description of working principles
Open the fuel cap to add kerosene/diesel in the tank. put on the fuel cap and plug the power cord in
the socket. Turn the power switch on to position "1", motor start working and the digital temperature
display light up at this time. The left display window is setting temperature and right one is room
temperature. It would ignite automatically when the setting temperature is higher than room. It begins
to work, the spark plug ignites. This heater is equipped with an electric air pump that forces air through
the air line connected to the fuel intake and then through a nozzle in the burner head. When the air
passes in front of the fuel intake it causes fuel to rise from the tank and into the burner nozzle. This
fuel and air mixture is then sprayed into the combustion chamber in a fine mist. The air blew by the
fast turning fan blades 1.enters the flame steady plate and the burner, supplies additional oxygen to
the burning and makes the burning more sufficient and takes away the heat from the burner interior to
outside2. enters the heat insulation layer of A, takes away the heat from the insulation layer,so that
the burner surface will not overheats.The spark plug stops working after 12s of sparkling.
45