bowl, tighten the union nut. Watch out! If you operate the pump in the filter bowl under
water, the skimmer must be connected to the inlet regulator or the inlet regulator
must be completely closed! To switch off the device, pull out the mains plug.
CLEANING AND MAINTENANCE
Before every cleaning and maintenance, make sure that the device is switched off and
disconnected from the power source.
The filter housing and the running unit must be cleaned at regular intervals. The cleaning
interval depends heavily on the degree of contamination. The degree of pollution can vary
significantly from body of water to body of water. First open the filter basket and take
out the pump motor. To clean the rotor and the inner parts, additionally remove the
corresponding screws and pull off the cover of the motor housing. The rotor can then
be easily pulled out of the liner and cleaned. Do not use sharp-edged objects such as
brushes for cleaning. Steel brushes, use a soft sponge instead. Stubborn stains such as
Limescale deposits are best removed with the premiumcare
pump cleaner. With sufficient flow, the pump is cooled by the water. Always make sure
that the pump works against as little resistance as possible. If the flow rate is reduced
(for example, if the hose diameter is too small, the ball valve in the line, the delivery height
is too high, contamination, etc.), the operating temperature rises significantly. Already at
55 degrees Celsius, lime deposits on the pump motor. In the worst case, this lime layer
becomes so thick that the rotor runs very stiff, blocked and the engine burns. Damage
caused by dirt and calcification is excluded from the guarantee. The user must properly
service and clean the pump depending on the amount of dirt and lime. After cleaning,
reassemble the pump in reverse order.
Observe the relevant product videos on
cleaning and maintenance
in our Youtube channel:
https://www.youtube.com/user/FIAPGmbH
WEAR PARTS
The pump must not run dry. Dry running leads to rapid wear and damages the pump
permanently. The use in contaminated water with solids and particles also leads to pre-
mature wear and negatively affects the life of the pump. Algae or others
Plants that settle around the filter basket and can clog it quickly lead to reduced water
flow and increased wear. We recommend operating the device exclusively in water wit-
hout plants or to ensure that no plants can be sucked in. Wear parts are excluded from
the warranty. Proper cleaning and care reduce wear on the device.
PUMPS
PUMP CLEANSER