Quick Start Guide
English
Features
0-10 V or 4-20 mA output, active, power supply
24 Vac/Vdc (3-4 wires) or 4-20 mA output, passive
loop, power supply from 16 to 30 Vdc (2 wires)
ABS V0 housing, IP65, with or without display
General features
Active sensor 0-10 V or 4-20 mA (24 Vac/Vdc power supply ±10%), 3-4 wires
Output / Supply
Consumption
European directives
2014/30/EU EMC; 2014/35/EU Low Voltage; 2011/65/EU RoHS II; 2012/19/EU WEEE
Electrical connection
PC Communication
Environment
Response time
Type of fluid
Tolerated overpressure
Conditions of use
(°C/%RH/m)
Storage temperature
Atmospheric pressure
transmitter
Measuring range from
800 to 1100 hPa
Indication of the pressure
in mbar, mmHG or hPa
"¼ turn" system mounting with wall-mount plate
Housing with simplified mounting system
Passive loop 4-20 mA (power supply 16/30 Vdc), 2 wires
Common mode voltage <30 VAC
Maximum load: 500 Ω (4-20 mA) / minimum load: 1 K Ω (0-10 V)
2 VA (0-10 V) or 0.6 VA (4-20 mA)
Screw terminal block for cables from 0.05 to 2.5 mm
2
or from 30 to 14 AWG
Carried out according to the code of good practice
USB-mini DIN cable
Air and neutral gases
< 10 seconds
Air and neutral gases
4136 hPa
From 0 to +50 °C. In non-condensing condition. From 0 to 2000 m
From -10 to +70 °C
Features of the housing
Material
Protection
Display
Height of digits: values: 10 mm; units: 5 mm
Connections
Cable gland
Weight
Symbols used
For your safety and in order to avoid any damage of the device, please follow the procedure described in
this document and read carefully the notes preceded by the following symbol:
The following symbol will also be used in this document, please read carefully the information notes
indicated after this symbol:
Connections
4
1
2
3
Inside the front housing
Removable front face
1. Inactive switch
4. LCC-S connection
6. Power supply
2. Active switch
5. Output terminal
block
7. Cable gland
3. Pressure connection
ABS V0 as per UL94
IP65
LCD 10 digits.
Dimensions: 50 x 17 mm
Ribbed, Ø 6.2 mm
For cables Ø 8 mm maximum
143 g
6
5
7
Fixed back housing