Using the machine interface
Job memories and reminders
Can be accessed via the «JOB» icon on the main screen.
The settings in use are automatically saved and remembered the next time you turn on the machine.
In addition to the current settings, it is possible to save and remember so-called «JOB» settings.
There are 500 JOBS for the MIG/MAG and TIG processes, as well as 200 for the MMA process. Data storage is based on the
current process settings, the current settings and the user profile.
Job
This JOB mode enables JOBs to be created, saved, remembered and deleted.
Quick-Load
– Recall JOBs from the trigger when not welding.
Quick Load is a non-welding JOB recall mode (20 max) and only possible in MIG-MAG and TIG processes.
From a list of previously created JOBs, JOB recalls are done by short trigger presses. All trigger modes and welding
modes are supported.
Error codes
The following table shows a non-exhaustive list of messages and error codes that may appear.
Carry out these checks and controls before contacting an authorised GYS technician.
If the user needs to open the product, they must turn off the power supply by unplugging the electrical plug and waiting two minutes
for safety.
Error codes
OVER VOLTAGE FAULT
001
Check the electrical installation
UNDERVOLTAGE FAULT
002
Check the electrical installation
005
Earth current fault.
COOLING UNIT FAULT
006
The cooling unit can no longer be detected.
FLOW RATE FAULT
007
Blocked cooling system
WATER LEVEL FAULT
008
Check the water level
COOLING GROUP
009
Thermal protection
GENERATOR
010
Thermal protection
Fan
011
Fan fault
TRIGGER
012
The trigger is pressed.
8
Messages
Solutions
Have your electrical installation checked by an authorised person.
There is a stray current. Check the wiring of the welding accessory
(torch, earth clamp, electrode holder, etc.)
Check the connection between the undetected cooling unit and the
power source.
Check the continuity of the coolant flow to the torch.
Fill the cooling unit's tank to the maximum (with coolant ref. 062511)
Wait a few minutes for the cooling unit to cool down.
Take care not to exceed the recommended duty cycle for the welding
current being used.
Ensure that air inlets and outlets are not obstructed.
Wait a few minutes for the power source to cool down.
Ensure that the recommended duty cycle for the welding current used
is not exceeded. Thermal protection Ensure that the air inlets and
outlets are not obstructed.
Installing a dust filter (ref. 063143). Please note that the dust filter
reduces the duty cycle.
Fan Switch off the power supply by unplugging the electrical plug and
check the fan. Ensure that the fan is not blocked.
Remove the torch and check that the message is still applicable
Check that the «Gas purge / Wire feed» switch is not obstructed or
stuck.
Check that the MIG/MAG torch trigger is not obstructed or stuck.