Screw-in flow controller
BFF T_ _ _ _-_ _002-_ _ _A0A-S4
Validity
This manual applies to screw-in flow controllers
BFF T_ _ _ _-_ _002-_ _ _A0A-S4.
Fig. 1:
Product illustration
Intended use
Together with the BAE SA-FF-055-RS (BAE00ZZ) signal
converter the flow controller is used for monitoring the flow
condition in pipelines and is intended for industrial use.
The flow controller is suitable for media which do not
cause the housing to corrode.
The flow controller is designed only for the purpose
described here and may only be used accordingly.
The technical specifications in this guide must be adhered to.
Improper handling or operation of the flow controller
beyond the technical specifications will make immediate
stoppage and an inspection by an authorized Balluff
service technician necessary.
Modifications to the flow controller or non-approved use
are not permitted and will result in the loss of warranty and
liability claims against the manufacturer.
Non-intended use
The flow controller may not be used in areas where
functional safety (SIL) is required or where malfunctions
can result in hazards to persons and equipment.
The flow controller may not be installed in explosion hazard
areas. Outgoing cables may not be routed in explosion
hazard areas.
The flow controller is a standard component and not a
safety device per MRL 2006/42/EG. For safety
applications a detailed assessment of the applicability of
the sensor per EN ISO 13849 or another applicable
standard by the system designer is required.
www.balluff.com

Downloading further instructions

This guide can also be downloaded from the Internet at
www.balluff.com.
Scope of delivery
Flow controller
2 × flat gasket made of AFM 34 (not for NPT)
This guide
Notes to the user
The device described in the guide has been designed and
manufactured according to the state-of-the-art.
All the components were subjected to strict quality and
environmental criteria during manufacture. Our
management systems are ISO 9001 certified.
This guide provides important information about use of the
device. Safe operation requires maintaining of all indicated
safety notes and handling instructions.
The local prevailing accident prevention regulations and
general safety codes must be maintained for the range of
application of the device.
The guide is a product component and must be kept near
the device where it can always be accessed by technical
personnel.
Technical personal must have carefully read and
understood the guide before beginning any work.
Function
The flow controller uses the calorimetric principle. Together
with a suitable signal converter it provides a flow-
dependent signal. It is installed in pipelines where it detects
flow rates which are within its specified working range.
The connected processing electronics evaluates the signal
from the flow controller and monitors it for under- or
overshoot of a preset limit.