Downloading Further Instructions - Balluff BTL7-S5 Serie Notice Résumée

Masquer les pouces Voir aussi pour BTL7-S5 Serie:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
BTL7-S5 _ _ ( _ )-M _ _ _ _ -A/B/Y/Z(8)-FA/KA _ _ -S115
Transducer — Rod Style
The CE Mark verifies that our products
meet the requirements of the current
EMC Directive.
Intended use
The Transducer, together with a machine controller (e.g.
PLC), comprises a position measuring system. It is
intended to be installed into a machine or system and
used in the industrial sector. Flawless function in
accordance with the specifications in the technical data is
ensured only when using original Balluff accessories. Use
of any other components will void the warranty.
Opening the transducer or non-approved use are not
permitted and will result in the loss of warranty and liability
claims against the manufacturer.
General safety notes
Installation and startup may only be performed by
trained specialists.
The operator is responsible for ensuring that local safety
regulations are observed. In particular, the operator must
take steps to ensure that a defect in the position
measuring system will not result in hazards to persons or
equipment.
If defects and unresolvable faults occur in the transducer, it
should be taken out of service and secured against
unauthorized use.

Downloading further instructions

A complete user's guide can be downloaded from the
Internet at www.balluff.com or requested via e-mail from
service@balluff.de.
13.5
~62
M12
KA00,3 = 0.3 m cable length
Version
D1
...-A/B/Y/Z-...
10.2 mm
...-A8/B8/Y8/Z8-...
8 mm
1
english
Mounting surface
B: 30-1 mm
Z: 2"-0.04"
3)
Magnet
0.5 Ø 25
25
71
Mounting surface
G
Thread M4x4/
6 deep
No thread
Dimensions and function
The transducer contains the waveguide which is protected
by an outer stainless steel tube (rod). A magnet is moved
along the waveguide. This magnet is connected to the
system part whose position is to be determined.
In normal operation, the LEDs indicate the operating states
of the transducer:
LED 1
Normal function
Green
Magnet is within the limits.
Red
Error
No magnet or magnet outside the limits.
LED 2
Green
Synchronous operation 2)
Internal measurement is synchronous to SSI
query.
Off
Asynchronous operation 2)
Internal measurement is asynchronous to SSI
query.
Flashing
Programming mode
green
Only with BTL7-S510...
1) Not for BTL7-...-FA_ _
2) Asynchronous operation is reached when the external sampling rate is
> f
or < 62.5 Hz (only with BTL7-S5_ _B/F-...).
A,max
Damping zone
Nominal length =
Measuring range
4)
Thread size
B: M18×1.5
Z: 3/4"-16UNF
A: 30-1 mm
A-SA211: 2"-0.04"
Y: 2"-0.04"
4
3)
Thread size
25
71
A: M18x1.5
Y: 3/4"-16UNF
3)
Unusable area
Not included in scope of delivery
4)
File no. 1)
E227256
3)
60
LED 1
LED 2

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Btl7-s5 m serie

Table des Matières