NOTES ON WORK AND PAUSE TIME PROGRAMMINGPAUSA
GB
This procedure is compulsory in new installations, to ensure that the control unit memorises the manoeuvre times and
a number of parameters used for obstacle detection.
Im or n no es be ore ro r mmin
- Power up the control unit and check correct operation of the command inputs by means of the corresponding LEDS
(the N.C. contacts must have the LED lit, and the N.O. contacts must have the LED off).
- Position the speed trimmers at the centre to obtain an average value.
- Clear the gate movement area.
PROGRAMMING TIMES
Procedure:
1- Position the gate at mid travel.
3- Keep the PROG key pressed.
4- After three seconds the LD1 LED lights up. After starting the programming procedure, release the PROG
button.
5- Press the S/S button to start the self-learning process. The gate starts with a closing manoeuvre.
6- When the closing manoeuvre is completed, the gate stops automatically.
7- After a few moments the gate starts with an opening manoeuvre.
when the desired opening point is reached.
9- The gate stops and the pause time memorisation phase begins.
10- If automatic reclosing is not used, press S/S immediately. Otherwise wait for the required pause interval then
press S/S. The motor begins the closing manoeuvre.
11- Gate completely closed
12- End of programming (the control unit sets automatically to normal operating mode).
* The memorised values remain stored until a new programming cycle is performed.