WARNING
Be sure to keep the special pilot screw provided with
this underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death
or serious injury to pool or spa users, installers or others
due to electrical shock.
3. Remove Junction Box cover, disconnect the light
fixture wires and strain relief, and then pull the cord
out of the conduit from the niche.
4. Feed the new light fixture cord through the conduit
from the niche to the Junction Box.
NOTE: Depending on the length of the conduit, special tools may
be required to pull the cord through the conduit.
5. Leave at least four (4) feet of cord to coil around the
light fixture or coiled into the base of the light niche,
see Figure 1 . This allows the light to be serviced
after the pool is filled with water.
6. Cut the cord at the Junction Box, leaving at least
six (6) inches of cord to make connections.
7. Strip six (6) inches of the outer cord jacket from the
cord to expose the three insulated wires. Be careful
not to damage the insulation on the three (3) inner
wires.
8. Install strain relief over cord jacket and connect the
light wires to the controller, black to orange, white
to orange, and green to the ground terminal bar.
Install the junction box cover.
9. Reinstall the light assembly into the niche and
tighten the special pilot screw.
WARNING
Use only the special pilot screw provided with this
underwater light. This screw mounts and electrically
grounds the housing securely to the mounting ring
and wet niche. Failure to use the screw provided could
create an electrical hazard, which could result in death
or serious injury to pool or spa users, installers or others
due to electrical shock.
10. Fill the pool until the underwater light is
completely submerged in water before operating
the light for more than 10 seconds. Turn on main
switch or circuit breaker, which operates the
underwater light, to check for proper operation.
Page 6
Jandy
Infinite WaterColors
®
Pool & Spa LED Lights | Installation & Operation Manual
WARNING
Never operate this underwater light for more than
10 seconds unless it is totally submerged in water. Without
total submersion, the light assembly will get extremely hot,
which may result in serious burns or in breakage of the
bulb or lens. This may result in serious injury to pool or spa
users, installers, or bystanders or in damage to property.
Section 4. Controller Wiring
Options
The Jandy Infinite WaterColors Pool & Spa LED Lights
are designed to be powered and operated with the
Jandy Infinite WaterColors LED Light Controller and
AquaLink RS (revision Y or later). Follow all installation
and operating instructions.
NOTE: The Jandy Infnite WaterColors LED Lights are dimmable
in the iAquaLink app and will not operate properly with
light dimmers. Do not wire the lights to any dimming
circuitry.
DO NOT CONNECT TWO OR MORE POWER SUPPLIES
IN PARALLEL.
4.1
Wiring to an AquaLink
System
The Jandy Infinite WaterColors LED Lights must be
wired into the Jandy AquaLink
AquaLink RS revision Y or later is required for
operation of the lights.
Refer to Figure 2 for the Infinite WaterColors Wiring
Diagram which shows light connections to the
controller and Aqualink system.
4.2
Wiring to the Light Controller
1. Knock out an opening in the right compartment.
2. Run low voltage light through a conduit connector
and secure to the enclosure.
3. Connect the low voltage wires black to orange and
white to orange.
4. Connect the ground wire to the bus bar.
Section 5. iAquaLink
Features
Download the iAquaLink app and/or upgrade to the
latest version prior to light and zone set up. App
function and design is subject to change.
5.1
Light Setup
1. Open the app on your device.
2. From My Systems page, select your pool.
3. From the home page, choose the cog system icon
on the top right and select System Setup.
RS Control
®
RS control system.
®
App
®