This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other
qualified agency¹)* in accordance with the manufacturer's instructions and all codes and
requirements of the authority having jurisdiction. Failure to follow instructions could result
in serious injury or property damage. The qualified agency performing this work assumes
responsibility for this conversion.
National Fuel Gas Code Z223.1 (Latest Edition)
1
*The term "qualified agency" means any individual, firm, corporation or company which either
in person or through a representative is engaged in and is responsible for (a) the installation
of gas piping or (b) the connection, installation repair, or servicing of equipment, who is
experienced in such work, familiar with all precautions required, and has complied with all the
requirements of the authority having jurisdiction.
Perform the safety shutdown test any time work is done on a gas system to avoid the possibility
of fire or explosion with property damage, personal injury or loss of life.
CHECK SAFETY SHUTDOWN SYSTEM
Intermittent Pilot System
1. Turn "OFF" using remote control. Main burner and pilot should go off.
2. Pilot gas flow should stop within 30 seconds.
Part Description
Main Burner Orifice, Front
Main Burner Orifice, Rear
SIT Gas Valve Conversion Kit
Gas Conversion Label
Target, Front
Target, Rear
TOOLS NEEDED:
Standard Screwdriver
1/4 Inch Hex Driver
41344-1-0220
GAS CONVERSION INSTRUCTIONS
DIRECT - VENT GAS FIREPLACE
CONVERSION KITS
Model
FOR CONVERSION TO NATURAL GAS
CHECK THE SAFETY SHUTDOWN PERFORMANCE
5/16 Inch Hex Driver
7/16 Inch Wrench
Empire Comfort Systems Inc. • Belleville, IL
WARNING
WARNING
PARTS LIST
Conversion Kit
P256
P211
R11381
1224
40277
40278
7/16 Inch Deep
Socket Set
Part No.
38227
Quantity Supplied
1
1
1
1
1
1
Page 1

Publicité

loading

Sommaire des Matières pour Empire Comfort Systems DVCT50CBP9-1

  • Page 1 FOR CONVERSION TO NATURAL GAS WARNING This conversion kit is to be installed by an Empire Comfort Systems, Inc., distributor (or other qualified agency¹)* in accordance with the manufacturer’s instructions and all codes and requirements of the authority having jurisdiction. Failure to follow instructions could result in serious injury or property damage.
  • Page 2 Figure 5. 8. Locate the orifice marked “41.” Use a 7/16 inch deep socket set to install orifice marked “41” onto front orifice holder. Use needle-nose pliers to screw front target onto orifice holder. See Figure 5. REAR REAR FRONT FRONT Figure 2 4. Remove (2) screws holding pilot assembly to burner pan. This will allow pilot assembly to drop. 5. Remove (2) screws holding burner base in place. Lift burner base out of firebox. See Figure 3. Figure 5 Figure 3 Page 2 Empire Comfort Systems Inc. • Belleville, IL 41344-1-0220...
  • Page 3 REAR AIR FRONT AIR SHUTTER SHUTTER SCREW SCREW FRONT OPEN CLOSED Figure 6 11. Use a 7/16 inch open wrench to loosen pilot body by slightly turning counter clockwise. Slide orifice bracket to other side and tighten pilot body clockwise. See Figure 7. “NAT” MARKING Figure 7 12. Replace items removed in steps 2-5 in reverse order. 13. Turn gas and electric on. 14. Gas conversion is completed. 41344-1-0220 Empire Comfort Systems Inc. • Belleville, IL Page 3...
  • Page 4 Empire Comfort Systems Inc. Belleville, IL If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer. www.empirecomfort.com Page 4 41344-1-0220...
  • Page 5 38227 POUR CONVERSION AU GAZ NATUREL AVERTISSEMENT Ce nécessaire de conversion doit être installé par un distributeur Empire Comfort Systems Inc. (ou une agence qualifiée )* conformément aux instructions du fabricant et à tous les codes et exigences de l’autorité ayant juridiction. Le défaut de respecter les directives pourrait résulter en de grave blessure ou dégâts matériels.
  • Page 6 Figure 4 Figure 2 7. Repérer l’orifice marqué « 32 ». Utiliser une clé à douille longue de 7/16 de pouce pour poser l’orifice 4. Retirer deux (2) vis qui fixent la veilleuse à la cuvette marqué « 32 » dans le porte-orifice arrière. Utiliser une du brûleur. Ceci permet à l’ensemble de veilleuse de pince à bec effilé pour visser la cible arrière dans le tomber. porte-orifice arrière. Voir Figure 5. 5. Retirer deux (2) vis qui maintiennent en place la base 8. Repérer l’orifice marqué « 41 ». Utiliser une clé à du brûleur. Soulever la base du brûleur hors du foyer. douille longue de 7/16 pour poser l’orifice marqué « 41 Voir Figure 3. » dans le porte-orifice avant. Utiliser une pince à bec effilé pour visser la cible avant dans le porte-orifice. Voir Figure 5. Page 2 Empire Comfort Systems Inc. • Belleville, IL 41344-1-0220...
  • Page 7 ARRIÈRE VIS DE VIS DE L’OBTURATEUR L’OBTURATEUR D’AIR AVANT D’AIR ARRIÈRE AVANT OUVERT FERMÉ Figure 6 11. Utiliser une clé ouverte de 7/16 po pour desserrer le corps de la veilleuse en tournant légèrement en sens antihoraire. Faire glisser l’attache de l’orifice de la veilleuse vers l’autre côté et le serrer en tournant en sens horaire. Voir Figure 7. INSCRIPTION « NAT » Figure 7 41344-1-0220 Empire Comfort Systems Inc. • Belleville, IL Page 3...
  • Page 8 Empire Comfort Systems Inc. Belleville, IL Pour toute question générale concernant nos produits, veuillez nous envoyer un courriel à info@empirecomfort.com. Pour toute question d’entretien ou de réparation, veuillez communiquer avec votre revendeur. www.empirecomfort.com Page 4 41344-1-0220...

Ce manuel est également adapté pour:

38227