GENERAL INFORMATION
This equipment is designed and sold for commercial use only by personnel trained and
experienced in its operation and is not sold for consumer use in and around the home nor for
use directly by the general public in food service locations.
First and foremost, each crate should be examined before signing the Bill of Lading to report
any visible damage by the trucker in transit and to account for the proper number of crates.
If there is apparent damage, arrangements should be made to fi le a claim against the carrier.
Interstate Commerce Regulations require that the claim must be initiated by the consignee.
Proper and secure storage facilities should be arranged for the oven(s) if necessary to protect
it from outdoor or damp conditions at all times before installation.
When you have all the crates unloaded, open the crates and remove all plastic covers. Inspect
at once for concealed damage. If anything appears to be damaged, contact the appropriate
persons immediately to fi le a damage claim. After completing this inspection, fi nish unpacking
the oven. Be sure to remove all paper protection and packing material from the unit prior
to lighting.
CAUTION
FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
The installation of the Appliance must conform to the NATIONAL FUEL GAS CODE
"ANSI Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND
REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT CAN/
CGA-B149.1 NATURAL GAS INSTALLATION CODE OR CAN/CGA-B149.2 PROPANE
INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
This appliance must be installed with a stand and casters designed by Star Manufacturing
as part of a complete installation. The installation must also include a connector complying
with either ANSI Z21.69 or CAN/CGA-6.16 and a quick-disconnect device complying with
either ANSI Z21.41 or CAN1-6.9. It must also be installed with restraining means to guard
against transmission of strain to the connector as specifi ed in the appliance manufacturer's
instructions.
For your protection, we recommend a qualifi ed installing agency install this appliance. They
should be familiar with gas installations and your local gas requirements. In any case, your
gas company should be called to approve the fi nal installation.
This appliance, its pressure regulator, and its individual shutoff valve must be disconnected
from the gas supply piping system during any pressure testing of that system at test pressures
in excess of 1/2 PSIG. This appliance and its pressure regulator must be isolated from the gas
supply piping system by closing its individual manual shutoff valve during any pressure testing
of the gas supply piping system at test pressures equal to or less than 1/2 PSIG.