F
Vent blockage test
After the dryer is installed, run the Vent Blockage Test function to check if the duct system is properly
installed. Vent Blockage Test automatically detects the status of the ducts and reports any blockage or
problems. Proper ducting can reduce drying time and save energy.
NOTE
The Vent Blockage Test function must run when the dryer is cool. If the dryer warms up after the
installation check, run the Air Fluff cycle for several minutes to reduce its internal temperature.
Running the vent blockage test
1. Make sure the drum is empty, and then close the door. (If there are any clothes or other items in the
drum, the test will not give accurate results.)
2. Tap
to turn the dryer on, then simultaneously tap and hold Options for 3 seconds.
3. Turn the Navigation dial to select Vent Blockage Test, and then tap OK. Vent Blockage Test starts
immediately.
-
The test takes about 2 minutes and "Testing..." is displayed during the test.
CAUTION
Do not open the door during the test.
NOTE
If you have started other procedures before running Vent Blockage Test, the dryer will not enter the Vent
Blockage Test mode.
4. After 2 minutes, when the test is complete, the results are displayed and the dryer sounds a tone. If
status of the duct system is normal, an alarm triggers with the "No problems detected" message. If the
duct system cannot exhaust properly, the check code appears, and the dryer sounds an alarm tone. For
description about the code, see the "Installation check codes" section on page 36.
If there are any other problems, an information code appears in the display. For description about the
code, see the "Information codes" section on page 62.
-
To stop or cancel Vent Blockage Test, tap
DV6900B_SimpleUX_WEB_Vent_EN.indd 35
8. Cover the back opening with a cover plate (F).
WARNING
Never leave the back opening uncovered. It must be
covered with a cover plate.
to turn off your dryer.
English
35
2022/6/7 14:49:30