Menu Structure
Display of sensor and system values
Displays the temperature of heating circuit 3 measured on the
sensor. This temperature is the controlled variable for heating
circuit 3.
Indicates if a request for heating has been made. Even if there is a
request present, it is possible that the heat pump will not operate
(e.g. because of the utility company shut-off time).
"Heating system flushing" is displayed when the system is being
flushed.
A HP block combined with a sufficiently high cylinder temperature
is indicated by "Bivalent-renewable".
Indicates which heat generator is available to carry out the heating
request
1: max. 1 compressor, 2: max. 2 compressors, 3: max. 2
compressors and a 2nd heat generator
Sensor for determining the defrost end with hot gas defrosting
Displays the temperature measured in the cylinder in bivalent-
renewable systems
Displays the measured return flow temperature during cooling
operation measured at the heat exchanger input
Displays the measured flow temperature during cooling operation
measured at the heat exchanger output
Displays the temperature measured on the "Antifreeze Cool"
sensor.
This temperature is used to safeguard the operating limits in
cooling operation.
Displays the temperature measured by the hot gas sensor
Displays the current room set temperature with silent cooling.
Displays the temperature measured in the room in which room
climate control station 1 is installed.
This temperature is the controlled variable for silent cooling.
Displays the humidity measured in the room in which room climate
control station 1 is installed. This value is used for calculating the
dew point with silent cooling.
Displays the temperature measured in the room in which room
climate control station 2 is installed.
This value is used for calculating the dew point with silent cooling.
Displays the current humidity in the room in which room climate
control station 2 is installed. This value is used for calculating the
dew point with silent cooling.
Indicates if a request for cooling has been made
Displays the current domestic hot water set temperature
Displays the measured domestic hot water temperature. This
temperature is the controlled variable for DHW preparation.
8.2
Display
Heating circuit 3
heating operation
At least 1 heating
circuit
Heating operation
Air HP with hot
gas defrosting
Bivalent -
renewable
Passive cooling
function
cooling operation
Cooling function
passive
Reversible HP
cooling operation
Reversible HP
Cooling function
silent cooling
cooling operation
Cooling function
silent cooling
or
room regulation
Cooling function
silent cooling
Cooling function
silent cooling
2 room stations
Cooling function
silent cooling
2 room stations
Cooling function
cooling operation
Hot water
sensors
Hot water
sensor
EN-11