ELECTRICAL CONNECTIONS
FOR 2 PHOTOCELLS
PH1
TX
1
2
POWER MODULE CONNECTIONS
V+
Limit switch/encoder power supply positive common (12 Vdc 50 mA MAX)
ENC
Encoder S signal input
NEG
Encoder power supply negative
M-
Motor output
Earth
M+
Motor output
CC24 ELECTRIC CONNECTIONS
SHIELD
Antenna - shield -
ANT
Antenna - signal -
COM
Common for FLASH, LED, SEN inputs / outputs
FLASH
Flashing light output 24Vdc (without regulation) maximum 25W
Courtesy light output 24Vdc (without regulation) maximum 15W (radio channel 4 selecting COURTESY LIGHT
LED
START = 2, COURTESY LIGHT TIME = 0 )
SEN
Ambient light sensor input
COM
IND output common
IND
Gate open warning light output, 24Vdc (without regulation) maximum 4W
COM
ELEC output common
ELEC
Electric lock output 12Vac, maximum 15VA
EDGE/EDGE
Sensitive edge output, NC contact or resistive 8k2
COM
STOP output common
Safety STOP NC contact between STOP and COM. This input is considered as a safety device; the contact may
STOP
be broken at any time, cutting out the automation at once and disabling all functions, including automatic closure
NEG
Photocell power supply negative output
PH-POW
Photocell power supply positive output, 24Vdc (without regulation, maximum 250mA
Photocells (closure), NC contact between PH1 and COM. The photocell is tripped at any time during closure of the
PH1
automation, stopping movement at once and reversing the travel direction
Photocells (opening), NC contact between PH2 and COM. The photocell is tripped at any time during opening and
PH2
closure of the automation, stopping movement at once; the automation will continue opening when the contact is
restored if it was opening, or continue closing if it was closing (see parameter "PHOTO 2")
COM
Common for PAR, OPEN, CLOSE and SBS outputs
PARTIAL opening command, NO contact between PAR and COM
PAR
Used to open the gate partially, depending on the software setting
PH1
PH2
RX
TX
1
2
PH2
RX
POWER MODULE
M1 - M2
M
EN
27