4
5
6
SBS
8
7
1. Control unit power supply connection 24 Vac
2. M1 power module socket
3. M2 power module socket
4. Programmer connector / SMART
5. Receiver compartment EM4X
6. Integrated STEP BY STEP control button does the cycle
(OPEN-STOP-CLOSE-STOP)
2.4 - Model and technical data of the control unit
Code
Description
Logic module for combination with 1 or 2 power modules for the control of 1 or 2 24V motors for swing and
CC24
sliding gates
• Power supply with protection against short-circuits inside the
control unit, on motors and on the connected accessories.
• Obstacle detection by means of current sensor.
• Anti-crush safety device.
TECHNICAL DATA
Power supply (L-N)
Rated power
Photocell power supply output
Flashing light output
Courtesy light output
Electric lock output
Gate open warning light output
Antenna input
Operating temperature
Accessory fuses
Power supply line fuses
Use in particularly acid, saline or explosive
atmospheres
M2
3
9
M1
2
7. External antenna connections
8. Input status indicator LEDs
9. Accessory/input connection terminal board
10. Protective fuse, 2.5AT
11. Battery connection
• Automatic learning of working times.
• Programmable deceleration during opening and closure.
• Safety input deactivation by means of software.
• Control panel with microprocessor logic.
CC24FULL
230Vac (+10% - 15%) 50/60 Hz
maximum 210W
24Vdc (without regulation) maximum 250mA
24Vdc (without regulation) 25W
24Vdc (without regulation) 15W
12Vac maximum 15VA
24Vdc (without regulation) 5W
50Ω RG58 type cable
-20 °C + 55 °C
2.5AT
2AT
NO
EN
11
1
10
23