STEP 14
Install Filters
To install filters for the following four steps (See Figure #7):
• Angle the filter into slots at the back of the hood.
• Push the button on handle of the filter.
• Release the handle once the filter fits into a resting position.
• Repeat to install all filters.
Problem
If the range hood or LED light
does not operate after installation:
The range hood vibrates when the
blower is on:
The blower or fan seems weak:
The lights work but the fan is not
spinning at all, is stuck or is rattling:
The hood is not venting out
properly:
Installation
Troubleshooting
Check if the range hood has been plugged in, make sure that all power
has been turned back ON, fused not blown and all electrical wiring are
properly connected.
The range hood might not have been secured properly on to the ceiling or
wall.
Check that the duct sized used is at least 6 in. (15.3 cm) or 3 1/4 x 10 in.
(8.3 x 25.4 cm). Range hood WILL NOT function efficiently with insufficient
duct size. For example: 7 in. (17.7 cm) duct over 6 in. (15.3 cm) hole and
loosely secured.
Check if duct is clogged or if damper unit (half-circular flange) is not
installed correctly or opening properly. A tight mesh on a side wall cap unit
might also cause restriction to the air flow.
The fan might be jammed or scraping the bottom due to shipping damage.
Please contact us immediately.
Make sure the distance between the stove top and the bottom of the hood
is within 24 in. and 30 in. (61 and 76.2 cm) in distance.
Reduce the number of elbows and length of duct work. Check if all joints
are properly connected, sealed, and taped.
— 15 —
Fig #7
Possible Cause