1.8
Choice of flue gas connection placement
The flue socket is fixed and located at the rear of the range. If the flue pipe is to be
connected on the side or on the top, the back wall connection must be covered with the
blind cover removed from the top or the side.
In the case of a connection from the top, the cover in the top of the range must be
removed and the emission nozzle must be installed.
If the flue pipe is to be connected from the side the procedure is as follows:
Remove the blind cover on the outside sidewall by removing the bolt.
Remove sidewall:
1.
Remove the blind cover (pull off forwards)
2.
Undo bolts in the sidewall.
Remove the blind cover on the inner sidewall by loosening the bolts and turning the
cover.
Take the flue connection from the back and mount it on the side.
Put the blind cover on the back to replace the flue connection which is now remounted
on the side. Tighten bolt.
Replace sidewall and blind cover.