5. Technical Data
Type
Total output
Heat output (level 1 / level 2)
Motor output
Control possibility
Voltage
Electricity (ventilate / level 1 / level 2)
Air volume
IP class
Length x width x height
Weight
6. Troubleshooting
ERROR
Appliance does not start
up
Appliance heats up, fan
does not run
If the appliance is supplied with electricity by the mains cable, work to the electrical
system can only be carried out by specialist electrical staff or a person trained in
electrical appliances in accordance with VBG 4.
Please only get repair work to the electrical appliance done by HEYLO service partners.
Discontinuing use and disposal of the appliance
The appliance has been designed for long term use.
If it has to be disposed of, please do so in accordance with the current relevant laws in an environment
friendly manner.
m³ / h
CAUSE
1.
Main switch switched off
2.
Indoor fuses tripped.
3.
Internal fuse (13A) has been
activated.
4.
Plug has been pulled out of the
main switch panel or extension
cable.
5.
Supply line defective.
6.
Mains switched off
7.
Safety temperature limiter tripped
8.
Indoor residual-current-circuit
breaker trips.
9.
Heating coil defective.
10. Fan defective
11
DE 9 XL
W
9000
W
4500 / 9000
W
52
°C
0° - 40°
V
400
A
6,5 / 13
550
24
mm
466 / 322 / 420
kg
14,5
SOLUTION
Check up to what point
electricity is available.
Repair defect.
Wait until electricity returns.
Check safeguards.
Appliance was overheated.
Repair source of error and
the appliance will switch
itself on again after waiting
for a while.
Clean heating coil (possibly
with compressed air)
otherwise send it to be
repaired.
Appliance could have come
into contact with moisture. If
yes, let it dry thoroughly
before operating it.
Send appliance to be
repaired
Send appliance to be
repaired
EN