OPERATING INSTRUCTIONS
Operation
17
General
17.1
When delivering air and other inert gases
normally water is used as ring liquid. Other ring
liquids than water may also be used in order to
meet with the requirements to the kinds of
gases and separators chosen. The ring liquid
has to be free from foreign bodies, as
otherwise the casing will be worne out. Use
appropriate filters to keep the pump free from
contaminants.
During operating temperature, the kinematic
viscosity should be at max. 4 mm
viscosity requires higher performance of drive.
The steam pressure of the ring liquid should be
at 16 mbar during vacuum operation at
working temperature; higher steam pressures
reduce the suction capacity and final vacuum
indicated in the performance tables resp.
characteristic curves. In case other ring liquids
than water will be used, the performance data
of the pump should be confirmed by us.
When delivering other liquids as well (ca.
2 times the volume of circulation liquid
indicated in the brochure) the supply of clean
liquid can be reduced considerably.
A condensation of steam in the vacuum pump
may
cause
cavitation
destroy parts of the pump. Therefore a
condensation before the vacuum pump is
preferrable
(injection
condensor etc.) In some cases the condensate
arising can also be delivered by the vacuum
pump. Otherwise a separate liquid ring pump
has to be provided. The specification should
be stipulated by the manufacturer/supplier.
The suction capacity listed (resp. the flux
volume listed) is reached by an operating
temperature of 15 ° C. An operation at higher
temperatures of operating liquid will cause a
reduced suction capacity (resp. a reduced
volume flow), however, gives the possibility of
safing fresh water resp. cooling liquid at open
resp. closed circulation cooling. Such liquid
quantity should be regulated by the regulating
r
valve r
resp.
only as high as the required
F
B
suction capacity (resp. the required volume
flow) will be reached. The regulating valve has
to be blocked at this position.
For vacuum operation with suction pressures
below 130 mbar it should also be taken care
that the operating water temperature should
not be below ca. 10 ° C, as otherwise the
suction nozzle gets covered with ice.
2
/s; higher
and
consequently
condensor,
surface
Fresh water requirement
17.2
For continuous cooling a fresh water quantity
according to diagram 1 is necessary.
The
fresh
water
circulation cooling will be made up according
to
diagram
1a
temperature difference
operating water minus temperature of fresh
water) has to be stipulated. In case that the
operating temperature is too high and the
vacuum is accordingly, cavitation will occur.
For operation with other speed rates as
indicated, the fresh water requirement has to
be converted proportionally to the change of
speed rate.
For closed circulation cooling the flux of
circulating liquid corresponds to the flux of
fresh liquid at continuous cooling.
25
requirement
for
open
and
1b.
For
that,
∆
t (temperature of
the