OPERATING INSTRUCTIONS
Commissioning
16
Decommissioning
Preparing for operation
16.1
For commissioning fill the pump with operating
liquid up to middle of shaft. This may be
effected
through
suction,
operating liquid pipe.
CAUTION
16.1.1.1.1 Dry run of the pump shall be
avoided by all means. Otherwise any
warranty
for
resulting
including
compensation of damages invalidate.
Check the direction of rotation. Wrong
direction of rotation leads to damages at
the pump.
V1/V6/V30/V55
In order to control the liquid level N, an
additional valve in the operation liquid pipe
may be provided (see illustr. 4b).
V95 - 430
In order to control the liquid level N a valve
may be connected to the connection U
automatic discharge valve at this connection
controls
and
regulates
automatically (illustr. 2a/4a).
Commissioning
16.2
Switch-on motor, open shut-off valve V
V
.
K
When starting operation with closed suction
side, open the ventilation device before
and close it after having reached the
operating speed.
Adjustment of flow volume
16.3
16.3.1 Open circulation cooling according
to illustration 2a
Open shut-off valve V
running and adjust regulating valve r
pressure at mano-vacuum meter m
(max. 0,2 bar). Block-up the regulating valve r
in this position. Maximum temperature of
operating liquid see 1.1. Then the vacuum
pump draws the quantity of clean water as
indicated in diagram 1.
discharge
or
any
consequences
claims
for
. An
V
the
liquid
level
resp.
F
while the pump is
F
that the
F,
is ca. 0 bar
B
F
16.3.2 Closed
according to illustration 3
While the vacuum pump is running adjust the
regulating valve r
F
vacuum meter m
B
bar from compression pressure.
The flux of cooling liquid K will be adjusted
through the regulating valve r
device. The regulating valves are to be
blocked.
16.3.3 Continuous cooling according to
illustration 4a
Open shut-off valve V
running and adjust regulating valve r
pressure at mano-vacuum meter m
(max. 0,2 bar). Then the vacuum pump draws
the quantity of clean water, as indicated in
diagram 1a.
16.3.4 For automatic systems according to
illustration 2b
The required temperature of operating liquid
has to be adjusted at the thermostatic
regulating valve r
regulator r
will be adjusted that the pressure
F3
at mano-vacuum meter m
considerably 0 bar.
Decommissioning
16.4
Close shut-off device V
motor, possibly open ventilation device h.
If the decommissioning is made to effect
any works at the pump, the drive must be
secured so that it cannot be switched on.
When using the pump for hazardous gases, it
has to be rinsed thoroughly before opening. In
order to prevent that easily inflammable gases
will cause an explosive air/gas mixture, the
pump has to be rinsed sufficiently with inert
gas before opening it and before restarting it
after opening.
In case of danger of frost or danger of
congealing of the ring liquid, pump and liquid
separator have to be emptied by withdrawing
all plugs at bottom. This is also applicable for a
longer shut-down period.
24
circulation
cooling
that the pressure at mano-
,
is differing no more than -0,2
at open shut-off
K
while the pump is
F
that the
F
,
is ca. 0 bar
B
The pressure reducing
F2
.
will not exceed
B
resp. V
, switch-off
F
K