Troubleshooting (continued)
Problem
The thermal overload protector cuts
out repeatedly.
The air receiver pressure drops
when the compressor shuts off.
There is excessive moisture in the
discharge air.
The compressor continuously runs.
The air output is lower than normal.
Possible Cause
There is low voltage from
the power source.
There is a lack of proper
ventilation, or the room
temperature is too high.
The wrong gauge wire or
length of extension cord is
being used.
The connections (fittings,
tubing, etc.) are loose
and leaking.
The drain valve is loose
or open.
The check valve is leaking.
There is excessive water in
the air tank.
The compressor is
working under a high
humidity environment.
The pressure switch
is defective.
An excessive amount of air
is being used.
The inlet valves are broken.
The connections (fittings,
tubing, etc.) are loose
and leaking.
18
Solution
Call an electrician.
Move the compressor to a well-
ventilated area.
Check for proper gauge wire and
cord length.
Check all connections with a soap
and water solution and tighten.
Tighten the drain valve.
Bring the compressor to a
service center.
Drain the tank.
Move the compressor to an area
of less humidity; use an air
line filter.
Bring the compressor to a
service center.
Decrease the air usage; the
compressor is not large enough
for the tool's requirement.
Bring the compressor to a
service center.
Tighten the connections.