"Electrically connect the appli-
4.
ance." → Page 35
Criteria for the installation
location
Follow these instructions when in-
stalling your appliance.
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
▶
space with a volume of at least
3
1 m
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate. → Fig.
The weight of the appliance ex works
may be up to 70 kg depending on
the model.
The subfloor must be of sufficient sta-
bility to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. → Fig.
Climate class Permitted room temperat-
ure
SN
10 °C to 32 °C
N
16 °C to 32 °C
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
/
1
3
/
1
3
Installation and connection en
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
Niche dimensions
Observe the niche dimensions if you
install your appliance in the niche. If
this is not the case, problems may
occur when installing the appliance.
Niche depth
Install the appliance in the recom-
mended niche depth of 560 mm.
If the niche depth is smaller, the en-
ergy consumption increases slightly.
The niche depth must be a minimum
550 mm.
Niche width
An inside niche width of at least
560 mm is required for the appli-
ance.
Preparing the appliance for
the first time
Remove the informative material.
1.
Remove the protective foil and
2.
transit bolts, e.g. remove the ad-
hesive strips and carton.
"Clean the appliance for the first
3.
time." → Page 39
Connecting the appliance to
the electricity supply
Insert the mains plug of the appli-
1.
ance's power cable in a socket
nearby.
The connection data of the appli-
ance can be found on the rating
plate. → Fig.
Check the mains plug is inserted
2.
properly.
a The appliance is now ready for
use.
/
1
3
35