5
RS-232C Interface (Continued)
RS-232C Communication Examples
This section shows the communication examples of RS-232C.
■
Operating command
Type
Connection
PC→This unit: 21 89 01 00 00 0A
check
This unit→PC: 06 89 01 00 00 0A
PC→This unit: 21 89 01 50 57 31 0A
Power (On)
This unit→PC: 06 89 01 50 57 0A
PC→This unit: 21 89 01 50 57 30 0A
Power (Off)
This unit→PC: 06 89 01 50 57 0A
Input
PC→This unit: 21 89 01 49 50 32 0A
(COMP.)
This unit→PC: 06 89 01 49 50 0A
Remote
PC→This unit: 21 89 01 52 43 37 33 32 45 0A
Control
This unit→PC: 06 89 01 52 43 0A
(MENU)
■
Reference command
Type
PC→This unit: 3F 89 01 50 57 0A
Power (On)
This unit→PC: 06 89 01 50 57 0A
This unit→PC: 40 89 01 50 57 31 0A
PC→This unit: 3F 89 01 49 50 0A
Input
This unit→PC: 06 89 01 49 50 0A
(HDMI 1)
This unit→PC: 40 89 01 49 50 36 0A
78
Others
Command
Command
Description
Connection check.
When power is turned on from
standby mode.
When power is turned off
(standby mode) from power-on
mode.
When video input is set to
component.
When the same operation as
pressing the [MENU] button
on the remote control is made
Description
When information of power-
on mode is acquired.
When information of HDMI 1
input is acquired.