I NSTAL L AT IO N
Gas Supply Line
NATUR A L G AS C O N NECT ION
Install the natural gas pressure regulator supplied with the
outdoor product with the arrow on the regulator pointing
towards the unit. Refer to the illustrations below for a typical
natural gas installation.
ADAPTER
VENT
CLOSE
NIPPLE
REGULATOR
REAR GAS
CONNECTION
BOTTOM GAS
FROM GAS
CONNECTION
TO GRILL
SHUT-OFF
VALVE
REGULATOR
Natural gas connection.
Natural gas regulator.
LP GAS CO NNECTI ON
For whole house LP gas connection, the LP gas pressure
regulator is not provided. It can be purchased from an
authorized Wolf dealer.
For connection to LP gas cylinder, use only an LP
pressure regulator that complies with national and local
regulations (EN 16129). Flexible hose should not be more
than 1.5 m, must be accessible for its entire length and
should comply with national and local regulations
(EN 16436-1).
Connect the
3
/
" flare end of the hose to the unit cou-
1
8
pling. Do not apply pipe sealant to the flare connection.
Install the LP gas cylinder. Pull out the shelf and place
2
the cylinder on it. Maximum height of cylinder is
SUPPLY
457 mm. Refer to the illustration below.
Ensure the gas valve on top of the cylinder is closed.
3
Connect the LP gas regulator to the cylinder and hand-
4
tighten only. Open the cylinder valve. Check for gas
leaks. Refer to the illustration below.
Tighten the LP tank retention screw to secure the
5
cylinder to the shelf.
WARNING
Perform a gas leak test each time the LP gas cylinder is
changed. Do not place more than one LP gas cylinder
in an enclosure at a time.
COUPLING
LP TANK
RETENTION SCREW
LP tank shelf.
LP gas cylinder connection.
LP G AS SA FE TY R E Q UI RE ME N T
This gas appliance and its individual shut-off valve must
be disconnected from the gas supply piping system during
any pressure testing of that system at test pressures greater
than 100 mbar.
This gas appliance must be isolated from the gas supply
piping system by closing its individual manual shut-off valve
during pressure testing of the gas supply piping system at
test pressures equal to or less than 100 mbar.
WARNING
FOR AUSTRALIA ONLY:
Built-in LP cylinder enclosures refer to AS5601.1.
GRILL
COUPLING
VENT
NUT
TO GRILL
REGULATOR
GA S L EA K TES TI NG
Perform a gas leak test at least once a year, each time the
LP gas cylinder is connected to the regulator and any time
part of the gas line is disconnected or replaced. This applies
to natural gas as well as LP gas.
Prepare a leak testing solution of half liquid soap and
1
half water in a spray bottle.
Verify all control knobs are in the
position.
2
Turn the cylinder valve knob counterclockwise one turn
3
to open.
Spray the leak testing solution on pipe joints, fittings and
4
hose. Bubbles in the solution indicate a gas leak.
Tighten any loose joint or replace any faulty part with a
5
Wolf replacement part to stop the leak. Do not attempt to
repair the cylinder valve. If damaged, the cylinder must
be replaced.
If the leak persists, shut off the gas supply at the cylinder
6
valve and remove the LP gas cylinder. Call Wolf factory
certified service. Do not use the outdoor product until
the leak has been fixed.
Push in and turn any control knob to the
position to
7
release pressure, then turn the control knob back to
WARNING
To prevent fire or explosion hazard, do not smoke or
permit sources of ignition in the area while performing
a gas leak test. Perform the gas leak test outdoors in a
well ventilated area. Never use an open flame to check
for gas leaks.
wolfappliance.com | 7
.