installing a hood that projects horizontally a minimum
of 5 inches beyond the bottom of the cabinet.
•
Verify that cabinets above the cooktop are a maximum
of 13" (330 mm) deep.
Appliance Handling Safety
•
Unit is heavy and requires at least two people or proper
equipment to move.
•
Hidden surfaces may have sharp edges. Use caution
when reaching behind or under appliance.
Safety Codes and Standards
•
This appliance complies with one or more of the
following Standards:
•
UL 858, The Standard for the Safety of
Household Electric Ranges
•
UL 923, The Standard for the Safety of
Microwave Cooking Appliances
•
UL 507, The Standard for the Safety of Electric
Fans
•
ANSI Z21.1, The American National Standard
for Household Cooking Gas Appliances
•
CAN/CSA-C22.2 No. 113-M1984 Fans and
Ventilators
•
CAN/CSA-C22.2 No. 61-M89 Household
Cooking Ranges
•
It is the responsibility of the owner and the installer to
determine if additional requirements and/or standards
apply to specific installations.
•
Installation must conform with local codes or, in the
absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1/NFPA 54.
•
The appliance must be electrically grounded in
accordance with local codes or, in the absence of local
codes, with the National Electrical Code ANSI/ NFPA
English 2
70, latest edition. (In Canada, installation must be in
accordance with the CAN 1-B149.1 and .2 Installation
Codes for Gas Burning Appliances and/ or local
codes).
Electric Safety
•
Before you plug in an electrical cord, be sure all
controls are in the OFF position.
•
For appliances equipped with a cord and plug, do not
cut or remove the ground prong. It must be plugged
into a matching grounding type receptacle to avoid
electrical shock. If there is any doubt as to whether the
wall receptacle is properly grounded, the customer
should have it checked by a qualified electrician.
•
This appliance should be installed in accordance with
the National Electric Code or Canadian Electrical
Code. It is required that the cooktop be installed on a
grounded, non-GFCI branch circuit.
•
Installer - show the owner the location of the circuit
breaker or fuse. Mark it for easy reference.
•
Important - Save these instructions for the local
electrical inspector's use.
•
Before installing, turn power OFF at the service panel.
Lock service panel to prevent power from being turned
ON accidentally.
•
Be sure your appliance is properly installed and
grounded by a qualified technician. Installation,
electrical connections and grounding must comply with
all applicable codes.
High Altitude Installation
This range is CSA certified for safe operation up to an
altitude of 10,000 ft. without any modifications (except LP
conversion, when applicable).