ELECTRICAL CONNECTION
The mains power supply must correspond to the rating indicated on the plate
situated inside the hood. If provided with a plug connect the hood to a socket in
compliance with current regulations and positioned in an accessible area, after
installation. If it not fitted with a plug (direct mains connection) or if the plug is not
located in an accessible area, after installation, apply a double pole switch in
accordance with standards which assures the complete disconnection of the
mains under conditions relating to over-current category III, in accordance with
installation instructions.
WARNING!
Before re-connecting the hood circuit to the mains supply and checking the
efficient function, always check that the mains cable is correctly assembled.
Replacing the power cable
The hood is provided with a special power cable ; if the cable is damaged,
request a new one from Technical Service.
AIR VENT
(for the suction versions)
Connect the hood and discharge holes on the walls with a diameter equivalent to
the air outlet (connection flange).
Using the tubes and discharge holes on walls with smaller dimensions will cause
a diminution of the suction performance and a drastic increase in noise.
Any responsibility in the matter is therefore declined.
!
Use a duct of the minimum indispensable length.
!
Use a duct with as few elbows as possible (maximum elbow angle: 90°).
!
Avoid drastic changes in the duct cross-section.
!
The company declines any responsibility whenever these regulations are
not respected.
FILTERING OR DUCTING ?
!
Your cooker hood is ready to be used in suction version.
To use the hood in filtering version the special ACCESSORY KIT must be
installed.
Check on the first pages of this manual if the ACCESSORY KIT is furnished
or must be bought separately.
Note: If furnished, in certain cases, the additional activated carbon filtering
system may be installed on the hood.
Information about the conversion of the hood from suction version to filtering
version is present in this manual.
Ducting version
In this case the fumes are conveyed outside of the building by means of a
special pipe connected with the connection ring located on top of the hood.
CAUTION!
The exhausting pipe is not supplied and must be purchased apart.
Diameter of the exhausting pipe must be equal to that of the connection ring.
CAUTION!
If the hood is supplied with active charcoal filter, then it must be removed.
Filter version
The aspirated air will be degreased and deodorised before being fed back into
the room.
In order to use the hood in this version, you have to install a system of additional
filtering based on activated charcoal.
CONTROLS
The hood is fitted with a control panel with aspiration speed selection control and
a light switch to control cooking area lights.
Models with mechanical control panel
T1. ON/OFF light switch
T2. Speed 1/OFF switch
T3. 2-speed selection
T4. 3-speed selection
Models with Soft Button panel + LCD Display
T1. Button ON/OFF suction motor
T2. Selection button for medium, high and intensive operating suction
speed (power).
Note: Intensive suction speed (power) intensiva (LED L1 flashing) lasts for
approximately 5 minutes, then the medium suction speed (power) is
automatically set.
T3. Selection button for 'silent' suction speed (power)
T4. Button ON/OFF lighting
L1. Status icon suction speeds (powers)
L2. Status icon saturation indicator for grease filter
L3. Status icon low (silent) suction speed (power)
L4. Status icon saturation indicator charcoal filter
L5. Status icon lighting
Reset filter saturation indicator
After performing maintenance of the filter, press and hold button T3, the icon
indicating saturation will switch off. Repeat the operation if both icons indicating
saturation (grease and charcoal) are on.
Activation of the icon for charcoal filter saturation
The icon for charcoal filter saturation is normally disabled. To activate it,
proceed as follows:
With the hood off, press and hold for a long time and simultaneously T1 and
T3: L4 flashes at first then it switches on with steady light to indicate
successful activation.
Disabling the icon for charcoal filter saturation: repeat the above
operation, L4 switches on with steady light then flashes and in the end
switches off to indicate successful disabling.
Automatic operation at high temperature
The hood is fitted with a sensor that detects the temperature. When this
becomes too high, the sensor automatically activates the medium suction speed
(power). The hood switches off when the temperature detected by the sensor
has lowered significantly.