If on the main panel (2), the water level control light (B) comes on during use and you would
like to continue using the steam cleaner, you will need to follow these steps:
1.
Unscrew the black water tank cap (4)
2.
Fill the tank with water (see water instructions for details).
3.
Place the tank cap (4) back on.
If you're using the trolley with the external water bottle connected to the water tank cap, fol-
low the same steps listed above but directed to the water bottle.
MAINTENANCE OF THE BOILER
To maintain your steam cleaner in good condition and to ensure consistent performance, we rec-
ommend that you clean the boiler once or twice a year depending on the hardness of the water.
CLEANING INSTRUCTIONS
ATTENTION: Before draining the boiler, please make sure that the machine is depressurized and
cool. Ensure that it is also disconnected from the power source.
1.
Take off the drainage cap at the bottom of the machine using a coin.
2.
Completely unscrew the boiler brass drainage nut from the boiler, using a 20 mm hexago-
nal key (19).
3.
To clean the boiler, we recommend using a descaling powder that can be purchased from
www.reliablecorporation.com
4.
Add the descaling powder with a mixture of warm water through the bottom of the boiler.
5.
Let the mixture of warm water and powder sit for 24 hours.
6.
Rinse thoroughly to ensure that all of the descaling powder has been removed
7.
After cleaning, twist close the drainage nut and replace the cap.
NOTE: if you see that the water that is coming out from the boiler is full of dirt/limestone, we
suggest that you repeat this operation more frequently, perhaps three to four times per year.
TECHNICAL DESCRIPTION
120V ~ Power
Cold water tank capacity
Boiler capacity
Working pressure
Continuous steam system (CSS)
Steam Regulations
Safety valve
Hot water injection
Limestone Magnetic Filter
Certifications
09
1750W
3,1L
1,6L
6 bar
Yes
3
Yes
Yes
Yes
cETLus