MAinTEnAnCE
IMPELLOR REPLAcEMENT
1
• Remove the right side
cover by removing 6
screws.
4
• Remove the 4 screws .
7
• Remove the impellor shaft
with pulley assembly
attached.
2
• Pull the belt tensioner (idler
arm) away from the drive
pulley. Be sure not to lose the
washer and screw left.
5
• Remove the left side cover
by removing 6 screws.
8
shaft sleeve
• Withdraw the old/damaged
impellor. Be sure not to
loose the shaft sleeve that
secures left side of the
shaft.
21
21
3
screw
Washer
• Remove the belt.
6
• Remove the nut that
secures the left side plate.
9
• insert the impellor shaft with
pulley assembly attached in the
new impellor. Be sure to replace
the retained shaft sleeve that
secures left side of the shaft.