The dust bag holding the dust and debris must be removed and renewed by authorised personnel, wearing appropriate
personnel protection, in a specified contamination area. Never operate without the full filtration system in place.
Process of disposal: Disconnect the hose, fit the Dust Cap on the Hose Flange, un-clip the bottom three Toggle Clamps (Upper
three toggle clamps have split pins that should not be removed by un-authorised personnel).
Remove the cloth filter in the Drum. Remove the dust bag from the Hose Flange inside the drum and seal the Dust Bag hole.
Place the Dust Bag inside an impervious plastic bag and seal the bag.
Dispose of the plastic bag, depending on contamination, in an appropriate manner.
Fully unwind the mains cable and connect the HASmachine into an approved power supply.
Unscrew the Dust Cap on the Hose Flange and fit Hose assembly plus appropriate tools for the job.
Preparing the machine for normal use
Fit a new Dust Bag over the Hose Flange inside the drum assembly. Refit the cloth
filter, and the Head, plus Interceptor assembly, re-applying the 3 Toggle clamps.
Ensure the dust bag (NVM-4B) has been properly fitted over Hose Flange
internally by unclipping the three lower toggle clamps, and lifting off Head &
Interceptor assembly.
If not fitted, fully insert dust bag over Hose Flange and re-fit the Head &
Interceptor assembly
To run the machine, press the ON/OFF button in.
Press once for ON, then press again for OFF