Page 2
- Intendend use: For measuring and control in heating and cooling systems. - The water quality requirements described in VDI2035 should be respected - TA-Smart can be cleansed with a damped cloth and a lenient cleaning agent. - Insulated wires and cables shall retard flame propagation with a flammability RATING of UL 2556 VW-1 or equivalent.
Page 3
If the TA-Smart is used in any other application than specified by IMI Hydronic Engineering the protection provided by the equipment may be impaired. Wird TA-Smart in einer anderen Anwendung als durch IMI Hydronic Engineering beschrieben verwendet, kann der vorgesehene Schutz der Geräte beeinträchtigt werden.
Page 4
Technical specifiactions valid at an altitude of max. 2000 m. Die technischen Spezifikationen sind nur bis zu einer maximalen Höhenlage von 2000 m über NN gültig. Spécifications techniques valables pour une altitude maxi de 2000 m. Specyfikacje techniczne obowiązujące na wysokości maks.2000 metros. -20°C - +70°C (-4°F - +158°F) (5-95%RH, non-condensing/nicht kondensierend/sans condensation/ bez kondensacji)
Page 7
Optional! Art. No./Artikel-Nr./No d’article/Nr artykułu G1/4 Wahlweise! DN 15-25 (3/4” - 1”) : 322230-00401, L = 14 mm (0.55 in.) Optionnel! DN 32-50 (1 1/4” - 2”): 322230-00400, L = 30 mm (1.18 in.) Opcja! > 70 mm (2.76’’) G1/4 ...
Page 8
LiYY or similar/oder ähnlich/ou similaire/lub podobny 40 mm 0,5-2 mm² (1.57 in.) (20-14 AWG) 7,5-8,5 mm (0.3-0.33 in.) 0.7 Nm ...
Page 9
Wiring diagrams/ Anschlussschema/Schéma de raccordement/ Schematy połączeń Terminal Description Klemme Beschreibung Borne Description Zacisk Opis Power supply 24 VAC/VDC. Spannungsversorgung 24 VAC/VDC. Alimentation 24 VAC/VDC. Zasilanie 24 VAC/VDC. Neutral for power supply 24 VAC/VDC and signals. Gemeinsamer Masseanschluss bei 24 VAC/VDC Versorgungsspannung und Signale. Neutre pour tension d’alimentation 24 VAC/VDC et signaux.
Page 10
HW00 HW01 To prevent any possible damage to the product caused by incorrect cabling or wiring, we have introduced a version of the TA-Smart PCBA (HW01) with improved electrical wiring. Both PCBA versions are fully functional, but have slightly different wiring configurations. Ensure to choose the correct technical documentation based on the PCBA's HW version.
Page 11
HW00 (Standard - Modbus RTU / BACnet MS/TP - Modbus TCP / BACnet IP) Standard HW00 Power Analog Ethernet RS485 L24 M Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) Note: 1. A, B and M terminals are NOT isolated from all other terminals. 2.
Page 12
Modbus RTU / BACnet MS/TP HW00 Power Analog Ethernet RS485 L24 M Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) GND (0V) Note: 1. A, B and M terminals are NOT isolated from all other terminals. 2.
Page 13
Modbus TCP / BACnet IP HW00 Power Analog Ethernet RS485 L24 M Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) 6 Green 3 Green-White 2 Orange 1 Orange-White Note: 1. A, B and M terminals are NOT isolated from all other terminals. 2.
Page 14
HW01 (Standard - Modbus RTU / BACnet MS/TP - Modbus TCP / BACnet IP) Standard HW01 Power Analog Ethernet RS485 L24 M RX - Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) Note: 1.
Page 15
Modbus RTU / BACnet MS/TP HW01 Power Analog Ethernet RS485 L24 M Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) GND (0V) Note: 1. A, B and M terminals are isolated from all other terminals. 2.
Page 16
Modbus TCP / BACnet IP HW01 Power Analog Ethernet RS485 L24 M Controller side 24 VAC/VDC 0 VAC/VDC 0(2)..10 VDC 0(2)..10 VDC or 0(4)..20 mA GND (0V) 6 Green 3 Green-White 2 Orange 1 Orange-White Note: 1. A, B and M terminals are isolated from all other terminals. 2.
Page 17
LED Colour Description Green – – – – – Status OK Green - - - - - - - - - - Initiating (start up) – – – – – Error (→ HyTune, Cloud, Bus) No power supply Blue –––––––––– Bluetooth active –...
Page 18
Operation Calibration Identification Betrieb Kalibrierung Identifikation En service Calibrage Identification Działanie Calibracja Identyfikacja 1-20% 1-20% 21-40% 21-40% 41-60% 41-60% 61-80% 61-80% 81-99% 81-99% 100% 100% HyTune app For setting of control parameters use HyTune app. Die HyTune App dient zum einstellen der Regelparameter. Pour le réglage des paramètres de régulation, utiliser l’application HyTune.
Page 20
We reserve the right to introduce technical alterations without prior notice. Wir behalten uns das Recht vor, technische Änderungen ohne Vorankündigung durchzuführen. Nous nous réservons le droit d’apporter des modifications techniques sans préavis. Zastrzegamy sobie prawo do wprowadzania zmian technicznych bez wcześniejszego powiadomienia..