Service tasks
9.6
Changing the vacuum pump oil
WARNING! Danger of fatal electric shock
!
Touching uninsulated parts may result in serious injury.
Switch off the AirConServiceCenter and unplug it from the power
supply before opening the housing.
The AirConServiceCenter may only be repaired by personnel
authorized by Dometic.
1. Before changing the oil, let the vacuum pump run for about
10 minutes (manually, via the menu).
2. Take off the front panel:
Undo the screws (D) on the control panel and lift it up. Then undo the
screws (E) on the bottom of the front panel and take it off.
3. Place a receptacle with a capacity of at least a ½ litre under the
AirConServiceCenter. The oil from the vacuum pump flows through
the opening (I) in the base of the device.
114
D
E
H
I
D
E
G
J
VAS 6746B