Télécharger Imprimer la page

Waeco AirConServiceCenter VAS 6746B Notice D'utilisation page 107

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 201
VAS 6746B
23. If necessary, use the keypad (8) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next
program step.
24. Deselect "Rec/Recycling phase ?" using No (the setting flashes)
and press ENTER to confirm.
25. Select "Vacuum phase ?" (the setting flashes) and press ENTER to
confirm.
26. If necessary, use the keypad (8) to enter the data and press ENTER
to confirm.
If no data is to be entered, press ENTER to switch to the next pro-
gram step.
27. Select "Filling phase?" (the setting flashes) and press ENTER to
confirm.
28. Enter the refrigerant filling quantity (note the oil filling quantity of the
compressor).
29. Then follow the instructions on the display (7):
Select the setting (which then flashes) and press ENTER to confirm.
30. Select "Process start ?" by pressing ENTER.
✔ After filling is complete, you will be prompted to disconnect the hoses
of the AirConServiceCenter from the vehicle air conditioning system.
31. Disconnect the service hoses (11) and (12) and press ENTER to
confirm.
The service hoses are then emptied. The device is then ready for
further use.
32. Put the valve caps of the vehicle air conditioning system back on the
connections.
EN
Operation
107

Publicité

loading