6
Mounting instructions
Inspecting the product
1
> Inspect the product for damages.
Preparing the water connection
2
The water connection can be prepared as follows:
– Via a permanent connection.
> Use an additional pre-installation set.
– Via ductwork in the cistern, often pre-assembled on
Duravit carrier frames.
> Check if ductwork is pre-assembled.
> Use an additional connection set.
Installing a noise reduction gasket
4
> Take the thickness of the noise reduction gasket into
consideration during installation: z + 50 mm (2 ").
Connecting the water
8
NOTE
Malfunctions caused by defective hoses
> Only use the water supply hoses provided with the
product. Do NOT reuse old hoses.
Installing the connection set for toilet
10
> Observe the seperate manual.
Do not bend or kink hose
13
> Ensure that the hose is not bent or kinked.
Flushing the pipes
17
NOTE
Malfunctions caused by dirty pipes
> Open the main valve for the water supply.
> Open the stop valve.
> Flush the pipes according to the local standards and
collect the water.
> Close the stop valve for the water supply.
Checking for leaks
> Check for leaks.
Choosing and installing mounting clip
23
The delivery contains several mounting clips.
> Choose the mounting clip according to cable diameter.
MI
Connecting the wires
25
WARNING
Risk of fatal injury caused by electric shock
Contact with electricity can lead to a fatal electric shock.
> Read and observe the information given in the safety
chapter of this manual.
> Remove approximately 10 mm (⅜") of insulation from
the wires.
> Connect the three wires to the terminal block.
Observe the L, N and PE conductors.
> Ensure that the protective earthing conductor is
10 mm (⅜") longer than the L and N conductors.
–
Installing interface with electronic actuator
28
29
plate (optional)
Depending on the model, it is possible to establish a
functional interface with the electronic Duravit actuator
plate. Some models can be connected via bluetooth after
installation. Other models require an empty pipe for an
interface cable pre-installed on the Duravit carrier frame
during shell construction.
> Confirm that an empty pipe for the interface cable is
pre-installed on the carrier frame.
> Install the interface set.
> Observe the seperate manual.
Checking for leaks
34
> Check for leaks.
Installation options remote control
37
– 1: Stuck onto the wall
– 2: Screwed onto the wall
+
Activating remote control
42
51
> Depending on the model, remove the transport lock
or connect the remote control to the charger.
+
Testing the product
44
53
> Check if the product works properly.
> Observe the user manual.
CAUTION
Damage to health caused by dirty, polluted or long
standing water
Operating the shower functions with dirty, polluted or
long standing water can cause damage to health.
> If the product is NOT to be used for two weeks or
more, empty the product and switch it off (holiday
mode).
70000785