Télécharger Imprimer la page

DURAVIT SensoWash D-Neo Compact Notice De Montage page 8

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 10
2.4
Hygiene
2.4.1 Damage to health caused by dirty, polluted or
long standing water
Operating the shower functions with dirty, polluted or
long standing water can cause damage to health.
> Supply the product with cold drinking water from the
main water system.
> Do NOT connect any waste water, grey water,
industrial water, sea water or other untreated or
semi-treated water.
> Only use the water supply hoses provided with the
product. Do NOT reuse old hoses.
> If the product is NOT to be used for two weeks or
more, empty the product and switch it off (holiday
mode).
2.5
Avoid product damage
2.5.1 General precautions
> Only use the parts in the installation kit to avoid
malfunctions.
> Only use attachments recommended by Duravit.
2.5.2 Damage through freezing water
> Do NOT install and operate the product in rooms
where there is a danger of frost. The room
temperature must not be less than 4 °C (39 °F).
2.5.3 Damage due to limescale build-up
Limescale can build-up in regions with hard water.
Limescale can impair the performance of the product.
> Check the water quality in the region. Duravit
recommends the installation of a water softener with
water hardness ≥ 14 °dH (2.5 mmol/l).
3
Requirements at the installation location
The pre-installation is carried out properly.
> Access the pre-installation data sheet at
qr.duravit.com or www.duravit.com.
> Ensure that there is enough floor space to install the
toilet and that bathroom door will open and close
without obstruction.
> Ensure that the lid will open and close without
obstruction against window frames, shelves and other
bathroom furniture.
8
24.02.20
57313
70000785
4
Drawings and plans
4.1
Water and power connections
180 mm
IG ½ "
90 mm
(3 ½ ")
> Ensure that the water connection and drain are
installed in the specified areas.
> Ensure that the electrical connection is installed in the
specified areas.
5
Technical data
Electrical connection
Rated voltage
Rated power
Circuit breaker
RCD
Protection degree
Protection class
Cable specification
Water connection
Cold water
Water pressure
Water hardness
(7 ⅛ ")
90 mm
(3 ½ ")
220 – 240 V, 50 – 60 Hz
1080 W
I
 = 16 A
N
I
 = 30 mA
N
IPX4
I
Supply line cross section
2
1 – 2.5 mm
(17 – 14 AWG)
DN 15 (1/2")
0.07 – 0.75 MPa
(10 – 109 psi)
Max. 2.4 mmol/l
(240 ppm)
MI

Publicité

loading