The state of charge is displayed by the battery charge indic-
ator (9) on the eBike battery and by the bars on the on-
board computer.
The LEDs on the eBike battery charge indicator (9) flash dur-
ing the charging process. Each continuously lit LED repres-
ents approximately 20 % of the charging capacity. The flash-
ing LED indicates the next 20 % currently charging.
Once the eBike battery is fully charged, the LEDs go out im-
mediately and the on-board computer is switched off. The
charging process is terminated. The state of charge can be
displayed for 3 seconds by pressing the on/off button (10)
on the eBike battery.
Errors – causes and corrective measures
Cause
eBike battery defective
eBike battery too warm or too cold
The charger is not charging.
Charging not possible (no indicator on eBike battery)
Connector not attached properly
eBike battery contacts dirty
Plug socket, cable or charger defective
eBike battery defective
Maintenance and servicing
Maintenance and cleaning
If the charger fails, please contact an authorised bike dealer-
ship.
Clean the charger using a dry cloth.
After-sales service and advice on using products
If you have any questions about the eBike and its compon-
ents, contact an authorised bicycle dealer.
For contact details of authorised bike dealerships, please
visit www.bosch-ebike.com.
Further information on the eBike components
and their functions can be found in the Bosch
eBike Help Center.
Bosch eBike Systems
Disconnect the charger from the mains and the eBike battery
or the eBike from the charger.
The eBike and eBike battery switch off automatically after
being disconnected from the charger.
Note: If you have charged the battery on the eBike, carefully
close the charging socket (6) with the cover (7) after char-
ging, so that no dirt or water can get in.
If the charger is not disconnected from the eBike battery
after charging, after a few hours the charger will switch itself
back on, check the state of charge of the eBike battery and
begin the charging procedure again if necessary.
Corrective measures
Two LEDs flash on the eBike battery.
Contact an authorised bike dealership.
Three LEDs flash on the eBike battery.
Disconnect the eBike battery from the charger until the char-
ging temperature range has been reached.
Do not reconnect the eBike battery to the charger until it has
reached the correct charging temperature.
No LEDs flashing (one or more LEDs will remain perman-
ently lit depending on the state of charge of the eBike bat-
tery).
Contact an authorised bike dealership.
Check all connections.
Carefully clean the eBike battery contacts.
Check the mains voltage, have the charger checked over by a
bike dealership.
Contact an authorised bike dealership.
Disposal and substances in products
You can find information about substances in products at the
following link:
www.bosch-ebike.com/en/material-compliance.
Do not dispose of eBikes and their components with house-
hold waste.
An in-store return is possible, provided the retailer voluntar-
ily offers a return or is legally obligated to do so. Refer to the
national regulations in this case.
The drive unit, on-board computer incl. operat-
ing unit, eBike battery, speed sensor, ac-
cessories and packaging should be disposed of
in an environmentally correct manner.
Check that your personal data has been deleted from the
device.
English – 3
0 275 007 XCX | (29.02.2024)

Publicité

loading

Ce manuel est également adapté pour:

Bcs230Bcs250