Télécharger Imprimer la page

Vulcan WOLF VCCB25 Manuel D'installation Et D'utilisation page 9

Publicité

Les langues disponibles

Les langues disponibles

LIGHTING THE GAS PILOT
1. Turn main gas shut-off valve and
the individual burner gas valves OFF.
Wait 5 minutes.
2. Remove the top grates and radiants.
Turn the main gas shut-off valve ON.
Light pilots using a lit taper. See Fig. 6.
Adjust the pilot valve screw until
the pilot flame has a slight yellow tip.
3. To light the burners, turn the
individual burner valves ON.
4. If the burners fail to light, turn all
valves and the main gas shut-off
to the OFF position and contact an
authorized service agency.
PILOT ADJUSTMENT
Using a flathead screwdriver, turn the
slotted hex-head pilot adjustment
screw clockwise to decrease the
flame, and counter clockwise to
increase the flame. See Fig. 7.
TO COMPLETELY SHUTDOWN THE BURNERS AND PILOT LIGHTS
For complete shutdown: Turn the main gas shut-off valve OFF. (Make sure all individual
burner valves are off before relighting.)
PREHEATING THE CHARBROILER
Allow the charbroiler to preheat for 30 minutes. Rub grates with cooking oil before using.
Pilot
Pilot Adjustment Screws
9
-
-
FIG. 6
Fig. 7

Publicité