1 - TECHNICAL SPECIFICATIONS
Control unit
Code
Type
Power supply
No. of motors
Motor power supply
Flashing light
Warning light
Electric lock
Accessory power supply
Radio receiver
Operating temperature
Degree of protection
2 - TECHNICAL SPECIFICATIONS/FUNCTIONS
• Red warning LEDs for the N.C. contacts (FCAM1-FCCM1-FCAM2-FCCM2-PHOTO-STOP).
• Green warning LEDs for the N.O. contacts (START-PED).
• Control of one 12VAC electric lock.
• Management of the opening release stroke to release the electric lock and of the final stroke to hook the electric
lock. Enabling the opening release stroke, you also activate the final stroke in closing (1s of extra motion).
• Working time learning by procedure or set with trimmer.
• Slow-down in opening and closing, only by run time learning procedure.
• Pause and leaf-delay time adjustment.
• Fixed or intermittent flashing light control.
• Courtesy light control.
• Programming of automatic closing.
• Photocell active during closing (operation during opening can be selected with a DIP switch).
• Motor force adjustment with appropriate trimmer.
• Operating range: Automatic - Step-by-step with stop - Pedestrian.
• STOP input control functioning as STOP (lock) or edge (obstacle freeing).
• Hydraulic lock upkeep for hydraulic motors (DIP1_10 ON).
• DIP switch to disable the LIMIT SWITCH and PHOTOCELL inputs if not used.
F4
AS06320
Electronic control unit for automation of
a swing gate, sliding gate, overhead door or barrier
with one or two 230 VAC motor
230 VAC single-phase 50/60 Hz
1 or 2
230 VAC
230 VAC 40W max
24 VAC 3W max
12 VAC 15W max
24 VAC 8W max
Plug-in
-20°C +60°C
IP55
13