Télécharger Imprimer la page

Broan Best WM24E Instructions De Montage page 12

Publicité

Les langues disponibles

Les langues disponibles

PREPARE THE HOOD
Note: Carefully remove the plastic
protective film from all exterior surfaces
of the hood and decorative flue, prior to
final installation.
1. To avoid demage while forwarding the
applicance has been locked by means of
four screws to a laminboard panel on the
bottom of the packing.
To separate the hood from the panel:
a.
Disassemble the central block: rotate
the block outside softly (Fig. 4).
b.
Remove the 4 screws (Fig. 5).
2. Fit the 2 brackets on the central block in
such a way that the two slots are plugged.
Each bracket must be fixed with (2) 3.9 x 6
mm mounting screws (Fig. 6).
3. Attach the discharge collar onto the hood
(Fig. 7); it must be attached by means of 4
mounting screws (3,9x9,5 mm Pan Head).
4. Remove the tape located on the damper
(Fig. 7).
5. Attach an adequate length of 8" round
steel ducting to the range hood discharge
collar (Fig. 8).
Duct tape all joints to make them secure
and air tight.
6. If the ductwork is placed on the wall (and
not on the ceiling), read the following
instructions:
- disassemble the motor block (included
the plate where it is fixed) unscrewing the
4 screws (Fig. 9).
- rotate motor block in order to have the
duct connector toward the wall.
MOUNTING SCREWS
(3.9x6mm)
BRACKETS
CENTRAL BLOCK
REMOVE THE TAPE
DISCHARGE COLLAR
FIG. 6
- 12 -
FIG. 4
FIG. 5
FIG. 7

Publicité

loading