WIRING
CAUTION: All electrical wiring should
be done by a qualified person (s) in
accordance with all applicable codes and
standards. This range hood must be
properly grounded. Turn off electrical
power at service entrance before wiring.
Do not turn power on at service panel until
all wires have been connected.
Blower connection at hood:
1. Run conductors (2-wire plus ground) from
the Exterior or In-Line Blower to the hood's
wiring box marked "motor connection".
See Fig. 1 if the ductwork is placed on the
ceiling; see Fig. 2 if the ductwork is placed
on the wall.
2. Remove the cover from the wiring box.
Fig. 1 or 2.
3. Secure the conduit to the wiring box
through a conduit connector. Fig.1 or 2
4. Make electrical connections at the hood.
Connect white-to-white, red-to-black and
green-to-ground. Fig.1 or 2.
5. Replace the wiring box cover and screws.
Make sure wires are not pinched between
the cover and box.
Exterior or In-line blower connection:
1. Make electrical connections at the
exterior or in-line blower (see instructions
provided with the exterior or in-line
blower).
BLOWER CONNECTION AT
HOOD (
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
BLOWER CONNECTION AT
HOOD (
CONNECT:
WHITE-TO-WHITE,
RED-TO-BLACK,
GREEN-TO-GROUND.
- 10 -
DUCTWORK ON THE CEILING)
Exterior or In-Line
blower
BOX MARKED
"MOTOR
CONNECTION"
DUCTWORK ON THE WALL)
Exterior or In-
Line blower
BOX MARKED
"MOTOR
CONNECTION"
FIG. 1
FIG. 2