IMPORTANT! Any installation operation shall be carried out by a suitably
trained staff, following carefully the information given in this manual.
Check the packaging at the reception of the goods and store only at a dry place. Verify that
the device has not been damaged during transport or storage operations. Make sure you
receive all the components. Ask the manufacturer for any possible missing component.
The hose reel has to be wall mounted at a minimum height from the floor of 2.50 m in
order to prevent accidents during work operations.
Considering the hose reel weight and dimensions, its movement requires the use of lifter
devices.In particular cases it is possible to mount it on the floor or on other machines as
accessory, only if complete with a fixed support.
The hose-guide arms can be fixed in three different positions according to the hose reel
installation (see pictures A-B-C page 27).
Mount the hose reel in fixed position or with revolving stand (optional) on stiff and consistent
walls using 4 dowels of 10 mm diameter (see drawing p.27).
WARNING! The manufacturer declines any responsibility for injuries to people or da-
mages to things caused by a wrong assembly of the hose reel.
Always connect the hose reel to the line by the couplers and the flexible hose (A) su-
itable for this use, above all in case of high pressure and temperature.
To avoid consequent loss of fluid tighten the fittings using appropriate keys, keep back
the swivel joints to avoid damaging them.
According to the rules, put a ball-tap on the feeding line of the hose reels in order to make
the maintenance operations easier. The said ball-tap can be used as a safety valve for dan-
gerous situations.
The connection hose is supplied as standard for models with swivel joint in composite materials.
9.1
9.2
IMPORTANT! For versions that mount hoses manufactured with materials suitable for
water passage for contact with food, before use carry out an adequate washing flow
of the parts in contact with the fluid.
8 - INSTALLATION
9 - LINK
9.1) Air/Water/Oil: Tighten the swivel joint on the shaft, fit the inlet
hose and the lateral cover.
9.2) Diesel fuel/Water 90°C (3/4"-1"): Tighten the swivel joint on
the shaft, fit the lateral cover and tighten the elbow on the
swivel joint using a suitable sealant.
9.3) Urea/Water 50°C (3/4"-1"): Mount the lateral cover and hand-
tighten the swivel joint, insert the hose into the hose connector
and fix it with the clamp.
IMPORTANT: Do not use sealants.
9.4) Oil (3/4"-1"): Tighten the swivel joint on the hub, fit the lateral
cover and tighten the elbow 90° on the swivel joint.