3. Connection terminals
4. Outlet with backdraught shutter
5. Cable entry
EN
The DECOR can either discharge di-
rectly to the outside or via an individual
or central ducting system (see Fig. 2).
The unit can be mounted on the wall
or ceiling using the 4 rubber blocks
and the screws provided.
Drill a hole in chosen position in the
wall or ceiling of: (fig.1).
If the unit is to be installed with indi-
vidual ducting, use a standard duct:
- DECOR-100: 100 mm
- DECOR-200: 125 mm
- DECOR-300: 150-160 mm
Loosen the screw (2), which holds
the grille in place (1) and remove the
grille. Ensure that there are no ob-
structions to the airflow and that the
impeller turns freely.
Fix the extractor to the wall in such a
way that it is not distorted in order to
avoid noise generation or problems
with the rotation of the impeller. Make
sure that the backdraught shutter
opens freely and has not being dam-
aged in transit.
Introduce the mains cable through one
of the cable point (5) and fix it to the wall
so that the fixing screw (2) is above.
Connect the electrical wiring as set
out below and then mount the protec-
tion grille (1) and tighten the screw (2).
ELECTRICAL CONNECTION
This appliance is consid-
ered to be suitable for use
in countries having a warm
damp equable climate as
14
specified in IEC 60721-2-1. It may also
be used in other countries.
The DECOR-100 is an extractor de-
signed for a single phase supply, with
voltage and frequency as indicated
on the rating plate of the unit. The
units are manufactured with double
electrical insulation (Class II) and
therefore they do not need an earth
connection.
In addition to the switch shown in the
installation drawing/diagram, there
must be an All Pole switch in the fixed
wiring with a contact opening of min
3 mm.
The electrical cable must enter the
DECOR-100 through one of the cable
point (5).
Once the cable has been introduced
proceed using the electrical wiring
diagram applicable to the selected
model.
DECOR S, C, SZ, CZ
These models use the following dia-
grams:
Fig.3: Fan operating through the light
switch.
Fig.4: Fan operating through an inde-
pendent switch.
DECOR R, CR, RZ, CRZ
These models are fitted with an ad-
justable timer. The timer enables the
fan to continue running for the select-
ed period after the switch has been
turned off.
Fig.5: Fan operating through an inde-
pendent switch.
Fig.6: Fan operating through a light
switch.