venting requirements
EN
2.6
elbow vent length values
Feet
0.03
15°
0.45
30°
0.9
45°
1.35
90°*
2.7
* The fi rst 90° offset has a zero value and is shown in the formula as - 90°
* The fi rst 45° and° offset have a zero value and is shown in the formula as -45° and -90° respectively
or -135° when combined (for 45° exit only).
2.7
top exit horizontal terminal
Simple venting confi guration (only one 90° elbow)
For vent confi gurations requiring more than one 90° elbow, the following formulas apply:
Formula 1: H
< V
T
Formula 2: H
+ V
T
Example:
V
= 3 FT (0.9m)
1
V
= 8 FT (2.4m)
2
V
= V
+ V
= 3 FT (0.9m ) + 8 FT (2.4m) = 11 FT (3.4m)
T
1
2
H
= 2.5 FT (0.8m)
1
H
= 2 FT (0.6m)
2
H
= H
+ H
= 2.5 FT (0.8m) + 2 FT (0.6m) = 4.5 FT (1.4m)
R
1
2
H
= .03 (three 90° elbows - 90°) = .03 (270° - 90°) = 5.4 FT (1.7m)
O
H
= H
+ H
= 4.5 FT (1.4m) + 5.4 FT (1.6m) = 9.9 FT (3m)
T
R
O
H
+ V
= 9.9 FT (3m) + 11 FT (3.4m) = 20.9 FT (6.4m)
T
T
Formula 1:
H
9.9 FT (3m) < 11 FT (3.4m)
Formula 2:
H
20.9 FT (6.4m) < 40 FT (12.2m)
Since both formulas are met, this vent confi guration is acceptable.
16
W415-2369 / E / 02.28.22
Inches
Millimeters
0.5
12.7
6.0
152.4
11.0
279.4
16.0
406.4
32.0
812.8
T
< 40 feet (12.2m)
T
< V
T
T
+ V
< 40 FT (12.2m)
T
T
(H
) < (V
)
T
T
See graph to determine the required vertical
rise V
for the required horizontal run H
T
The shaded area within the lines represents
acceptable values for H
.
T
and V
T
T