en Troubleshooting
Malfunctions
Errors
Appliance no longer re-
sponds.
Appliance only dispenses wa-
ter, not coffee.
Appliance is not dispensing
milk froth.
No milk intake by the milk sys-
tem.
Milk froth is too cold.
70
Cause
Appliance has a fault.
Empty bean container is not
detected by the appliance.
Coffee shaft on brewing unit is
blocked.
Beans are too oily and are not
falling into the grinder.
Brewing unit is not inserted
properly.
Milk system is soiled.
Milk tube not immersed in
milk.
Heavy build-up of limescale in
the appliance.
The milk system is assembled
incorrectly.
Order for connecting the milk
container and milk system is
wrong.
Milk tube not immersed in
milk.
Milk is too cold.
Troubleshooting
Pull out the mains plug and wait
1.
10 seconds.
Re-insert the mains plug.
2.
Pour in coffee beans.
Clean the brewing unit.
→ "Cleaning brewing unit", Page 64
Gently tap the bean container.
Change the coffee variety.
Do not use oily beans.
Clean the empty bean container with
a damp cloth.
Slide the brewing unit right back.
Clean the milk system in the dish-
washer.
→ "Cleaning the milk system",
Page 62
Use more milk.
Check whether the milk tube is im-
mersed in the milk.
Descale the appliance.
→ "Using the descaling programme",
Page 65
Assemble the milk system correctly.
→ "Cleaning the milk system",
Page 62
First insert the milk system into the
outlet and then the milk container.
Use more milk.
Check whether the milk tube is im-
mersed in the milk.
Use lukewarm milk.