EcoNet RETST800SYS Guide De L'utilisateur page 31

Publicité

Les langues disponibles

Les langues disponibles

Thermostat Settings
Installer Settings
80
80
Resume Schedule
Group 1
Furnace
AC/HP
Thermostat
71
75
36
Air Handler
Defaults
Home
Away
Warning! These settings are to be used
Refrigeration
Cooling to
by a qualified HVAC contractor ONLY
34
65
70
BACK
Thermostat Settings
80
80
Thermostat Brand
Rheem
Resume Schedule
Group 1
71
75
36
Aux Heat Hold Off Time
Auto
Filter Check Hour
9 am
Anticipator
0
Home
Away
Refrigeration
Cooling to
70
34
65
BACK
The higher the negative
The higher the positive
number the faster the system
number the longer the system
will cycle off, increasing the
will stay cycled on, lowering
number of times the system
the number of times the
cycles off in an hour.
system cycles off in an hour.
-5
-4
-3
-2
-1
0
1
2
Factory set default
and
recommended
rate of equipment
cycling.
Air Handler Settings
Installer Settings
80
80
Resume Schedule
Group 1
Furnace
AC/HP
Thermostat
71
75
36
Air Handler
Defaults
Home
Away
Warning! These settings are to be used
Refrigeration
Cooling to
by a qualified HVAC contractor ONLY
70
34
65
BACK
Air Hander Settings
80
80
Electric Heater Size
None
Resume Schedule
Group 1
71
75
36
EXV Superheat Offset
0° F
O Input Fan Control
Off
Away
Home
Aux #1 Config
N.O.
Off
Aux #2 Config
N.O.
Off
Refrigeration
Cooling to
Filter Type
Media
70
65
34
BACK
> Return to Table of Contents
Go to Menu > Settings > Installer (tap and hold) > Thermostat.
!
44%
44%
UNITS
Thermostat Brand – The EcoNet Smart Thermostat will automatically
!
populate when the system starts up by reading the equipment's model data card.
Aux. Heat Hold Off Time – This setting is designed to keep the auxiliary heat
44%
44%
off for a duration of time determined by the user. The time periods are:
• Auto: The thermostat will energize Aux Heat once the temperature has
UNITS
reached 1 full degree beyond the heat set point. Also if the heating
system is not maintaining the set point using the heat pump alone.
• 1-60 min: The number of minutes the system will keep the Aux Heat
from coming on even when the space temperature goes beyond 1 degree.
Filter Check Hour – The time of day when the EcoNet Smart Thermostat will
check the air filter status.
Anticipator – Gives the user the ability to accurately control the system
from overshooting in the Heating and the lag of delivering conditioned air in
the cooling mode. When set to 0 the system will use the factory default and
recommended rate of equipment cycling to maintain comfort. Increasing
3
4
5
the number will slow down the system, causing longer cycles. Reducing the
number will make the system react quicker, shortening the equipment cycle.
Go to Menu > Settings > Installer (tap and hold) > Air Handler.
!
44%
44%
UNITS
Electric Heater Size – If electric strip heaters are installed in the air handler
!
you will need to select the appropriate size.
Electric Heat Airflow Select – Four choices available. Refer to air handler
44%
44%
installation instructions for air flow settings.
UNITS
See pages 28-29 for the G Input and AUX Input details. These settings are the
same for both furnace and air handler.
EcoNet
Smart Thermostat User Guide
®
31