Télécharger Imprimer la page

EcoNet RETST800SYS Guide De L'utilisateur page 14

Publicité

Les langues disponibles

Les langues disponibles

Settings (con't)
Settings (con't)
Settings
80
80
Resume Schedule
Group 1
75
71
36
Basic
Time
Home
Away
Away
Vacation
Refrigeration
Cooling to
70
65
34
BACK
Dehumidification
80
80
Enable Dehumidification?
Yes
Resume Schedule
Group 1
71
75
36
Dehumidify Set Point
52 %
Over-Cooling Amount
0 ºF
Dehumidify Drain Timer
5 min.
Home
Away
Refrigeration
Cooling to
70
65
34
BACK
HUMIDIFICATION
Humidification
80
80
Enable Humidification?
No
Resume Schedule
Group 1
75
71
36
Humidify Set Point
30 %
Humidify During...
Heat
Smart Control
Off
Home
Away
Humidity With Fan
Off
Refrigeration
Cooling to
34
65
70
BACK
> Return to Table of Contents
!
Humidity Settings (Menu > Settings > Humidity)
Humidity
44%
44%
Control your home's humidity settings for more ideal comfort.
Fan
Installer
UNITS
!
Dehumidification (Menu > Settings > Humidity)
44%
44%
Enable Dehumidification – The system will attempt to reduce humidity
in cooling mode by reducing fan speed and over-cooling the space (when
UNITS
allowed by the Over-Cooling setting). The system will only reduce airflow if
the room temperature is within one degree of set point, otherwise, full cooling
airflow will be performed.
Dehumidify Set Point – The indoor relative humidity to be controlled to while
in cooling mode.
Over-Cooling Amount – The system will activate cooling, and possibly over-
cool the space by the desired number of degrees to improve dehumidification
performance in an effort to reach the dehumidify set point. The factory setting
for over-cooling is zero (no over-cooling) and can be adjusted up to 5 degrees
of over-cooling.
Dehumidify Drain Timer – At the end of a cooling cycle, if set, the continuous
fan setting will be turned off for the selected amount of time in order to drain
water from the indoor coil.
!
Humidification (Menu > Settings > Humidity > Humidification)
44%
44%
Enable Humidification – The system can control a humidifier attached to the
furnace or air handler to increase humidity in the space. It is important to note
UNITS
you cannot humidify above the dehumidification set point.
Humidification Set Point – This setting allows you to choose the indoor
relative humidity desired, under which humidification will activate. The default
is humidification set point is 30% and is configurable between 15 and 45%.
Humidify During – Select the modes in which humidification will be
performed. Humidification can occur during heating, continuous fan and/or
cooling mode.
• Heat – Humidifier will operate with equipment during Heat if a
humidification demand is present.
• Heat/Fan – Humidifier will operate with equipment during these modes if
a humidification demand is present.
• Heat/Fan/Cool – Humidifier will operate with equipment during these
modes if a humidification demand is present.