Main Switch
1
Gently press the main switch. A green LED
will light and the gyro motor will start to ro-
tate. (Fig. 6)
2
Wait for about a minute until the gyromotor
reaches operating speed.
Lock Lever
1
When operating the STABISCOPE with your
left hand, raise the lock lever in the direction
of the arrow mark, as illustrated; when op-
erating with your right hand, lower it in the
direction of the arrow mark. When the lock
lever is released, the target can be observed
without vibration or shakiness of the image.
(Fig. 7)
2
As described in the condition of 1 above,
when the lock lever is released, a red LED
positioned by the lock lever will light.
3
The red will blink on· and off if the lock lever
is released while the main switch is in the off
position. Be careful not to let this condition
continue for a long period.
When observation is not being performed or when the gyro motor is not rotat-
ing (when the main switch is OFF), keep the lock lever in the "LOCK" position.
d
CAUTION!
Please be careful not to carry the STABISCOPE when the lock lever is released :
such action may result in problems.