Table - Cooking-end audible signal time set-
ting
Cooking-end audible
signal level
0
1
2
3
3-Ventilation Mode setting (
ü This device is used in 2 modes: Internal
circulation and external circulation
mode. (Ventilation modes) The device
comes pre-set in accordance with the
internal circulation mode. To change;
1. Turn on the cooker by touching the
key, and turn it off by touching
again.
2. Within 10 seconds after turning off the
product, touch
spectively.
ð Default setting
played on the timer screen.
3. Touch key four times for ventilation
mode setting.
ð Appears on the timer screen
"1" appears on the left rear cooking
hob zone display.
4. Ventilation mode can be set as external
circulation by touching the setting area
of the left rear hob zone or by swiping
your finger over the area, the hotplate
screen is brought to "2".
5. Confirm the ventilation mode setting by
touching the
key.
ð » The appliance will turn off and
your appliance starts to work with
the selected level of ventilation
setting.
4 - Life display of the active carbon fil-
ter(
)
ü The activated carbon filters in the
product, when used for internal circula-
tion, require replacement after a spe-
Cooking-end audible sig-
nal period
15 seconds
30 seconds
1 minute
2 minute
)
key
/
/
/
keys re-
will be dis-
cific period of use. You can check the
remaining working hours for the filters
on the
maining time is displayed on the
screen as a countdown from 150
hours.
Ensure to replace the activated car-
bon filters in your product after
every 150 hours of operation,
provided it is operating in internal
circulation mode. After 150 hours,
the
symbol appears on the vent-
ilation display. This warning symbol
does not appear if your product is
set to external circulation mode.
1. Turn on the cooker by touching the
key, and turn it off by touching
again.
2. Within 10 seconds after turning off the
product, touch
spectively.
ð Default setting
played on the timer screen.
3. Touch the key
ated carbon filter life screen.
ð "On the timer display
ally on the left rear hotplate dis-
play, the remaining operating
hours for the activated carbon fil-
ter are indicated as follows: '3' for
over 100 hours, '2' for 50-100
hours, '1' for 5-50 hours, and '0' for
0-5 hours."
4. By touching the
can be closed.
5 - Reset display of the active carbon filter
(
)
After 150 hours of operation, the
appears on the ventilation display. As a res-
ult of removing and replacing the active
carbon filters as described in the mainten-
ance-cleaning section, the following steps
are followed to reset the display:
EN / 23
settings screen. The re-
/
/
/
keys re-
will be dis-
five times for the activ-
, specific-
key setting display
EN
IT
FR
key
symbol