English
Draining the Tank
To help prevent tank corrosion and keep moisture out of the
air used, the tank of the compressor should be drained daily.
To drain:
● Verify that the compressor is turned off.
● Holding the handle, tilt the compressor toward the drain
valve so that it's set in a lower position.
● Open the drain valve by rotating it ¼ turn counterclockwise.
● Keep the compressor tilted until all moisture has been
removed.
● Drain moisture from tank into a suitable container.
NOTE: Condensate is a polluting material and should be
disposed of in compliance with local regulations.
● If drain valve is clogged, release all air pressure by pulling
the safety valve. Remove and clean valve, then reinstall.
Fig. M
Drain valve (closed)
WARNING: Unplug the air compressor and
release all air from the tank before servicing.
Failure to depressurize tank before attempting to
remove valve may cause serious personal injury.
● Close the drain valve by rotating it ¼ turn clockwise.
Checking the Safety Valve
DANGER: Do not attempt to tamper with safety
valve. Anything loosened from this device could
fly up and hit you. Failure to heed this warning
could result in death or serious personal injury.
The safety valve will automatically release air if the air receiver
pressure exceeds the preset maximum. The valve should be
checked before each day of use by pulling the ring by hand.
● Turn the air compressor on and allow the tank to fill. The
compressor will shut off when the pressure reaches the
preset maximum.
● Turn the air compressor off.
● Pull the ring on the safety valve to release air for three
to five seconds.
● Release the ring. Air must immediately stop escaping when
the ring is released. Any continued loss of air after releasing
the safety valve ring indicates a problem with the safety
14
Fig. N
Drain valve
(open)
End of Operation/Storage
● Turn the ON/OFF switch to the OFF (O) position.
● Unplug power cord from wall outlet and wrap around handle
● Wearing safety glasses, drain tank of air by pulling the ring
● Drain tank of condensation by opening drain valve on
● Air hose should be disconnected from compressor and hung
● Compressor and hose should be stored in a cool, dry place.
valve. Discontinue use and seek service before continued
use of the air compressor.
WARNING: If air leaks after the ring has been
released, or if the valve is stuck and cannot
be actuated by the ring, do not use the air
compressor until the safety valve has been
replaced. Use of the air compressor in this
condition could result in serious personal injury.
area to prevent damage when not in use.
on the safety valve. Use other hand to deflect fast moving
air from being directed toward your face.
bottom of tank. Tank pressure should be below 10 PSI
when draining tank.
open ends down to allow any moisture to drain.
6