Usage limitations
MODELS
Gate-leaf length (m)
Leaf weight (kg)
400
MODELS
Gate-leaf length (m)
Leaf weight (kg)
400
For leaves longer than 2.5 m, install an electric lock.
Technical data
MODELS
Motor power supply (V)
Power (W)
Capacitor (μF)
Current draw (A)
Operating temperature (°C)
Storage temperature (°C)*
Thrust (N)
Opening time at 90° (s)
Motor thermal protection (°C)
Sound pressure level (dB A)
Protection rating (IP)
Insulation class
Reduction ratio (i)
Weight (kg)
Average life (cycles)**
(*) Before installing the product, keep it at room temperature where it has previously been stored or transported at a very high or very low temperature.
(**) The average product life specified should be understood purely as an indicative estimate. It applies to normal usage conditions and where the product has been
installed and maintained in compliance with the instructions provided in the CAME technical manual. The average product life is also affected, including significantly,
by other variables such as, but not limited to, climatic and environmental conditions. The average product life should not be confused with the product warranty.
Operating cycles
MODELS
Cycles/hour (no.)
Consecutive cycles (no.)
The cycles calculation applies to gates that are professionally installed, free of any mechanical issues and/or accidental friction points, and measured at 20°C, as
stated in EN Standard 60335-2-103.
Cable types and minimum thicknesses
Cable length (m)
Power supply 230 V AC
Motor power supply 230 V AC
When operating at 230 V and outdoors, use H05RN-F cables compliant with 60245 IEC 57 (IEC); when indoors, use H05VV-F cables compliant with 60227 IEC 53
(IEC). For power supplies up to 48 V, use FROR 20-22 II cables compliant with standard EN 50267-2-1 (CEI).
If the cable lengths differ from those specified in the table, define the cable cross-sections according to the actual power draw of the connected devices and in
line with regulation CEI EN 60204-1.
For multiple, sequential loads along the same line, recalculate the values in the table according to the actual power draw and distances. For information on
connecting products not covered in this manual, please see the documentation accompanying the products themselves.
ATS30AGS
3
2,5
2
-
600
800
ATS30AGR
3
2,5
2
-
600
800
ATS30AGS
230 AC
250
8
1
-20 ÷ +55
-20 ÷ +70
400 ÷ 3000
15
150
≤70
54
I
28
8.5
120.000
ATS30AGS
20
10
ATS50AGS
5
4
3
2,5
400
500
600
800
ATS50AGR
5
4
3
2,5
400
500
600
800
ATS50AGS
ATS30AGR
230 AC
230 AC
250
250
8
8
1
1
-20 ÷ +55
-20 ÷ +55
-20 ÷ +70
-20 ÷ +70
400 ÷ 3000
400 ÷ 3000
20
15
150
150
≤70
≤70
54
54
I
I
28
28
9
8.5
120.000
120.000
ATS50AGS
ATS30AGR
20
20
10
10
up to 20
3G x 1.5 mm²
4G x 1.5 mm²
ATS50AGM
2
5
4
3
2,5
1000
400
500
600
800
ATS30AGM
2
3
2,5
2
1000
400
600
800
ATS50AGR
ATS50AGM
230 AC
230 AC
250
250
8
8
1
1
-20 ÷ +55
-20 ÷ +55
-20 ÷ +70
-20 ÷ +70
400 ÷ 3000
400 ÷ 3000
20
20
150
150
≤70
≤70
54
54
I
I
28
28
9
9
120.000
120.000
ATS50AGR
ATS30AGM
20
20
10
10
from 20 to 30
3G x 2.5 mm²
4G x 2.5 mm²
2
-
1000
-
ATS30AGM
230 AC
250
8
1
-20 ÷ +55
-20 ÷ +70
400 ÷ 3000
15
150
≤70
54
I
28
8.5
120.000
ATS50AGM
20
10